SRDB ID   Synopsis   Date
23897   src/p card causes e450 to fail boot with upa-port error.   29 Sep 2000

Status Issued

Description

Description

Enterprise 450 is loaded with Solaris 2.x and is fully functional. 
The src/p IO card is added to the appropriate slot in the back of 
the 450, and cabled to the middle 8 drive back plane of the array.
The addition of the card is verified at the Open Boot Prom level. 
Diagnostics such as "probe-scsi-all" and "obdiag" appropriately
identify the card. However reboot of the system now fails with:
          
        warning: pci6:no upa-port id property

The only way to get the system to boot again is to remove the 
card from the slot.

                              
SOLUTION SUMMARY:

Solution

The problem is solved at the OBP level. The minimum PROM revision
required for the src/p card is 3.12.12. In this particular case, the 
PROM version was 3.5. By installing patch 106122-06 (or later) and 
upgrading the PROM to the latest level, (in this case 3.16.2), the 
system booted up normally. 

Note: the same PROM requirement exist for the E250. The PROM upgrade
      patch is 106503-04 or later.
                              

INTERNAL SUMMARY:

Internal Section

SUBMITTER: Daniel Caporale PATCH ID: 106122-06, 106503-04 APPLIES TO: AFO Vertical Team Docs/Storage ATTACHMENTS:


Copyright (c) 1997-2003 Sun Microsystems, Inc.