SRDB ID |
|
Synopsis |
|
Date |
24961 |
|
220R / 420R misrepresent the system type in prtdiag |
|
9 May 2001 |
Note: prtdiag is located in /usr/platform/`arch -k`/sbin/ and must be run with
UID 0
When prtdiag is run on a 420R/220R, it reports the system type as an
Ultra80/Ultra 60, respectively. It reports this because a 420R/Ultra80 and a
220R/Ultra60 share the same type of system board.
SOLUTION SUMMARY:
To change this information, type the following from a terminal window: (as root)
# eeprom banner-name="Sun Enterprise 420R"
# eeprom enclosure-type="540-4115"
# eeprom energystar-enabled?=false
Similar commands can be given at the OK prompt, and they are:
ok setenv banner-name Sun Enterprise 420R
ok setenv enclosure-type 540-4115
ok setenv energystar-enabled? false
INTERNAL SUMMARY:
SUBMITTER: David Brezee
APPLIES TO: Hardware, AFO Vertical Team Docs/Hardware
ATTACHMENTS:
Copyright (c) 1997-2003 Sun Microsystems, Inc.