SRDB ID |
|
Synopsis |
|
Date |
25477 |
|
A3x00/A1000/rm6 - LUNS show up with 'sd' driver instead of 'rdriver' |
|
20 Feb 2001 |
On an A3x00 or A1000 configured with LUN numbers greater than 7, LUNS
whose numbers are greater than 7 show up using a different hardware
path that that of LUNS 0 through 7.
This different hardware path will show up in /dev/rdsk, /dev/dsk, as
well as in 'format.' For an example, see the following snippet from
the output of the 'format' utility:
8. c3t4d4 <Symbios-StorEDGEA3000-0205 cyl 17192 alt 2 hd 64 sec 64>
/pseudo/rdnexus@8/rdriver@4,4
9. c3t4d5 <Symbios-StorEDGEA3000-0205 cyl 17192 alt 2 hd 64 sec 64>
/pseudo/rdnexus@8/rdriver@4,5
10. c3t4d6 <Symbios-StorEDGEA3000-0205 cyl 17192 alt 2 hd 64 sec 64>
/pseudo/rdnexus@8/rdriver@4,6
11. c3t4d7 <Symbios-StorEDGEA3000-0205 cyl 17192 alt 2 hd 64 sec 64>
/pseudo/rdnexus@8/rdriver@4,7
12. c3t4d8 <Symbios-StorEDGEA3000-0205 cyl 17192 alt 2 hd 64 sec 64>
/sbus@2,0/QLGC,isp@2,10000/sd@4,8
13. c3t4d9 <Symbios-StorEDGEA3000-0205 cyl 17192 alt 2 hd 64 sec 64>
/sbus@2,0/QLGC,isp@2,10000/sd@4,9
Notice how LUNs 8 and 9 show a path without the 'rdnexus' and 'rdriver'
paths.
SOLUTION SUMMARY:
This problem is usually due to the fact that the '/etc/osa/rmparams'
file has the parameter "System_MaxLunsPerController" set to 8.
To fix the problem, set the value of this parameter to the correct
value (typically 16 or 32) and perform a reconfiguration reboot on the
system.
This problem may manifest itself after any of the following scenarios:
1. Adding or removing patches or packages that reference the
/etc/osa/rmparams file. This might have the effect of setting the
values in this file back to their defaults.
2. Upgrading the 'rm6' software and forgetting to make this change to
the rmparams file.
3. Performing the procedure to allow 16 or 32 LUN support, but leaving
out the step of editing this parameter in this file.
INTERNAL SUMMARY:
SUBMITTER: Chris Kiessling
APPLIES TO: Hardware/Disk Storage Subsystem/StorEdge Disk Array/StorEdge A1000, Hardware/Disk Storage Subsystem/StorEdge Disk Array/StorEdge A3000, Hardware/Disk Storage Subsystem/StorEdge Disk Array/StorEdge A3500, Storage/RAID Manager, AFO Vertical Team Docs/StarOffice
ATTACHMENTS: