SRDB ID | Synopsis | Date | ||
26872 | Sun Fire (3800-6800): Anomalies in showboards power status | 14 Aug 2001 |
Status | Issued |
Description |
After removing a power supply or fan tray, the results of the showboards command shows that the power is still ON. Also, poweron/poweroff are confused in this situation, that is, poweron still thinks the component is still ON.
SOLUTION SUMMARY:
This is a bug documented in bugid 4448419. The current workaround is to reboot the SC.
INTERNAL SUMMARY:
Authors: Rick Holmes/John Cecere
SUBMITTER: George Bolduc APPLIES TO: Hardware/Sun Fire ATTACHMENTS: