SRDB ID   Synopsis   Date
28497   Why all Sunray Appliances don't get login prompt   19 Nov 2001

Status Issued

Description

Rather than getting a login prompt, the Sunray Appliance hangs at the hour glass with 2 dashes.

Executing utadm -p on the server gives the following error:

"error: no interfaces configured"

SOLUTION SUMMARY:

Usually when all the appliances hang at the hour glass with 2 dashes, it means waiting for DHCP. Check if in.dhcpd is running or not. This daemon can be started by running /etc/init.d/dhcp start on the Sunray server.

If the Sunray server has only one interface, then the above error will appear. The Sunray server should contain 2 interface cards. One for the regular network and the second for the Sunray interconnect. Configured interfaces can typically be seen by running utadm -p.

INTERNAL SUMMARY:

SUBMITTER: Nimisha Amin APPLIES TO: ATTACHMENTS: