SRDB ID |
|
Synopsis |
|
Date |
28503 |
|
Boot from Sun StorEdge[TM] A1000 fails with error: cannot assemble drivers for /pseudo/rdnexus... |
|
26 Jun 2002 |
Booting from an Sun StorEdge[TM] A1000 fails with the following errors :
cannot assemble drivers for /pseudo/rdnexus@1/rdriver@0,0:a
cannot mount root on /pseudo/rdnexus@1/rdriver@0,0:a
Seen with: Raid manager 6.11u2, Solaris[TM] 7
After changing the Raid Module Name, the next reboot fails with :
cannot assemble drivers for /pseudo/rdnexus@1/rdriver@0,0:a
cannot mount root on /pseudo/rdnexus@1/rdriver@0,0:a
when booting to an A1000.
SOLUTION SUMMARY:
Solution:
boot the system using cdrom -sw.
mount / from the LUN0 on A1000 to /a.
Check the /a/etc/system file for the correct forceloads (rdriver and rdnexus).
Make sure the files rdriver, rdnexus and rdriver.conf exsist under /a/kernel/drv.
Check the module name in /a/etc/osa/mnf.
Make sure the mname in /a/kernel/drv/rdriver.conf file has the same mnf file module name. If
it is different edit /a/kernel/drv/rdriver.conf and change the mname="OLDNAME" to mname='NEWNAME' which is the mnf file module name.
Make sure you change the mname values for all the entries in /a/kernel/drv/rdriver.conf whose parent="/pseudo/rdnexus@1"
Umount /a
Now the system will boot from A1000.
keywords: A1000, StorEdge, Solaris, cannot, assemble, drivers, pseudo, rdnexus@1/rdriver@0,0:a
INTERNAL SUMMARY:
Srinivas Josyula
Srinivas.josyula@east.sun.com
Internal bug: 4493823
SUBMITTER: Srinivas Josyula
APPLIES TO: AFO Vertical Team Docs/Storage
ATTACHMENTS:
Copyright (c) 1997-2003 Sun Microsystems, Inc.