41697 | Sun StorEdge [TM] T3 - Warning: Device has not been removed from the slot and is still in the loop map | 1 Mar 2002 |
Status | Issued |
Description |
When trying to physically remove a Sun StorEdge [TM] T3 Disk Tray from a server using luxadm, the following error message is reported.:
# luxadm remove_device [-F] <WWN T3 > "Device: <pathname> Warning: Device has not been removed from the slot and is still in the loop map."
This error is reported after physically removing the T3 and hitting <Return>:
SOLUTION SUMMARY:
1. # luxadm remove_device -F <WWN T3>
2. Once the prompt tells you to remove the device, and you hit <Return>, telnet into the Sun StorEdge T3 Disk Tray and unmount all volumes
3. On the server performing the luxadm remove_device command, hit <Return> to remove the device paths from the OS.
INTERNAL SUMMARY:
sophia.hill@sun.com