SRDB ID |
|
Synopsis |
|
Date |
42763 |
|
FD REMAINS IN FDD error on SE9900 series array |
|
20 Sep 2002 |
------- SIM 01 Follows: ----------------------------------------------------
Severity: Moderate SIM Time: Jan 30, 2002 03:00:01
SIM Type: DKC
Reference Code: 7C0000
Type: SVP ERROR
Description: FD REMAINS IN FDD
Action Codes:
Code: F0100000
Location:
Function: EJECT FLOPPY DISK
Additional: -
SIM Bytes:
Byte: 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15
Data: 00 90 10 00 00 00 8F E0 11 40 00 00 00 00 7C 0C
Byte: 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
Data: 22 00 A0 A7 00 04 7C 00 01 10 00 00 F1 00 04 00
----------------------------------------------------------------------------
SOLUTION SUMMARY:
The solution is to have someone eject the floppy from the floppy drive. After ejecting the floppy you will need to hit a key to enable the SVP to boot. Once the SVP is fully booted you need to clear the SIM that was generated.
SUBMITTER: Mark Reid
APPLIES TO: Storage, Hardware/Disk Storage Subsystem/StorEdge Disk Array/StorEdge 9900