SRDB ID | Synopsis | Date | ||
42949 | Sun Enterprise[TM] 10000: panic cannot allocate i/o mmu tsb arrays | 10 Sep 2002 |
Status | Issued |
Description |
On an E10K, when booting net the domain panics with:
panic cannot allocate i/o mmu tsb arrays
This is an issue with the designation of the O/S for the domain and the boot image. When defining the domain, the O/S should be specified as 5.6, 5.7 or 5.8. If the O/S is specified as 2.8 for instance insead of 5.8, the domain will panic when it is booted over the network.
SOLUTION SUMMARY:
Solution: To change the O/S designation, for ssp 3.3 and above do:
ssp% domain_rename -d <domain name> -o <correct O/S version>
For lower versions of the ssp,
ssp% domain_remove -d <domain name>
When it asks if you want to delete the files, make sure to retain the files.
The domain can then be recreated with the correct O/S by:
ssp% domain_create -d <domain name> -o <correct O/S version>.
Keywords: E10000, starfire, E10K, mmu, tsb
INTERNAL SUMMARY:
SUBMITTER: Dennis McDonald APPLIES TO: Hardware/Ultra Enterprise/Servers/Enterprise 10000, AFO Vertical Team Docs/HAS ATTACHMENTS: