43200 | Sun StorEdge[TM] 9900 Series Remote Console does not accept password after installation. | 27 Feb 2002 |
Status | Issued |
Description |
Remote Console doesn't accept default USER and p/w=USER after initial installation.
Missing file C:\Hirmc\com\user.lst
SOLUTION SUMMARY:
1) De-Install RMC (Remote Console) then make a fresh installation from diskette or CD ROM using exactly the method in the RMC manual.
That is, using the Windows Start>Run... and
enter source drive:\setup.exe
or
2) Copy the file from source drive:\config\com\ to c:\hirmc\com\
INTERNAL SUMMARY:Contributed by John.Adams@sun.com
SUBMITTER: George Bolduc APPLIES TO: Hardware/Disk Storage Subsystem/StorEdge Disk Array/StorEdge 9900 ATTACHMENTS: