SRDB ID   Synopsis   Date
43210   Sun Fire[TM] 15K server: Duplicate Open Boot Prom (OBP) devaliases may prevent the system from booting   27 Feb 2002

Status Issued

Description

Check the sysconfig/prtconf-vp.out file for duplicate devalias entries. If any duplicates are found, determine if the duplicate entries reference different devices. If any duplicates are found to reference different devices, the system may fail to boot. Devalias entries in prtconf-vp.out are displayed in a system Node with a name of "aliases" (see the node example below).

Example devalias Node entry from prtconf-vp.out. Note that the duplicate alias "disk" would fail this check. The duplicate alias disk5 would not fail, because both entries reference the same device. Also, note the node name field at the bottom of the Node entry.

Node 0xf081ffb0
        xdisk:  '/ssm@0,0/pci@18,700000/pci@1/SUNW,isptwo@4/sd@0,0'
        xnet:  '/ssm@0,0/pci@18,700000/pci@1/SUNW,hme@0,1'
        diskc:  '/ssm@0,0/pci@1c,700000/pci@1/SUNW,isptwo@4/sd@0,0'
        netc:  '/ssm@0,0/pci@1c,700000/pci@1/SUNW,hme'
        cdrom:  '/ssm@0,0/pci@18,700000/pci@1/SUNW,isptwo@4/sd@6,0:f'
        disk:  '/ssm@0,0/pci@18,700000/pci@1/SUNW,isptwo@4/sd@0,0'
        disk:  '/ssm@0,0/pci@18,700000/pci@1/SUNW,isptwo@4/sd@1,0'
        disk0:  '/ssm@0,0/pci@18,700000/pci@1/SUNW,isptwo@4/sd@0,0'
        disk1:  '/ssm@0,0/pci@18,700000/pci@1/SUNW,isptwo@4/sd@1,0'
        disk2:  '/ssm@0,0/pci@18,700000/pci@1/SUNW,isptwo@4/sd@2,0'
        disk3:  '/ssm@0,0/pci@18,700000/pci@1/SUNW,isptwo@4/sd@3,0'
        disk4:  '/ssm@0,0/pci@18,700000/pci@1/SUNW,isptwo@4/sd@4,0'
        disk5:  '/ssm@0,0/pci@18,700000/pci@1/SUNW,isptwo@4/sd@5,0'
        def-cn:  '/sgcn'
        diskifp:  '/ssm@0,0/pci@19,700000/SUNW,ifp@1/ssd@0,0'
        diskglm:  '/ssm@0,0/pci@18,700000/scsi@2/disk@0,0'
        scsi:  '/ssm@0,0/pci@18,700000/pci@1/SUNW,isptwo'
        net:  '/ssm@0,0/pci@1c,700000/pci@1/SUNW,hme@0,1'
        disk5:  '/ssm@0,0/pci@18,700000/pci@1/SUNW,isptwo@4/sd@5,0'
        name:  'aliases'      

SOLUTION SUMMARY:

Delete the duplicate devalias entries from the OBP. Note, this must be done from the OBP OK> prompt, and will require system downtime to complete. Use the command "nvunalias " to remove each of the duplicate entries. Ensure that the nvramrc is not set to recreate one of the duplicate aliases unintentionally. Note that a "reset" may be required on the system before the duplicate aliases will not appear in the output of a "devalias" command. Then, recreate the appropriate aliases with the "nvalias" command.

INTERNAL SUMMARY:

ERAS Check 975

SUBMITTER: George Bolduc APPLIES TO: Hardware/Sun Fire /15000 ATTACHMENTS:


Copyright (c) 1997-2003 Sun Microsystems, Inc.