SRDB ID | Synopsis | Date | ||
43211 | Sun Fire[TM] 15K server: Domain Automated System Recovery (ASR) is disabled for one or more domains. | 27 Feb 2002 |
Status | Issued |
Description |
If Domain Automated System Recovery (ASR) is disabled, the System Management Software (SMS) will take no action to recover a domain in the event of a failure. For example, if a domain with ASR disabled panics, no automated steps will be taken to POST and reboot the domain.
SOLUTION SUMMARY:
Domain Automated System Recovery (ASR) should be enabled at all times unless specifically directed by Sun Engineers.
Set "domain_asr = 1" in all dsmd_tuning.txt files.
The platform configuration file is located at /etc/opt/SUNWSMS/config/dsmd_tuning.txt.
Domain specific configuration files are located in /etc/opt/SUNWSMS/config/A-R.
INTERNAL SUMMARY:
ERAS Check 1953
SUBMITTER: George Bolduc APPLIES TO: Hardware/Sun Fire /15000 ATTACHMENTS: