SRDB ID   Synopsis   Date
45885   Sun Fire[TM] 3800-6800: Rebooting a domain after firmware update to 5.12.6 fails   17 Jul 2002

Status Issued

Description

BugID: 4592308

Symptom: After using flashupdate to update a system, the next reboot of the domain results in the following error:

Oct 22 12:58:38 ds2-sc0 Domain-A.POST: ERROR: Failed to decompress Open 
Firmware image ({/N0/SB0/P0}  failed to decompress Open Firmware image)            
SOLUTION SUMMARY:

Workaround:

Issue a setkeyswitch off on the domain, and then setkeyswitch on. This will reset the domain.

Notes:

This problem can be avoided by following the instructions on page 8 of the 5.12.6 Software Release Notes.

Keywords: flashupdate, firmware, 5.12.6

INTERNAL SUMMARY: SUBMITTER: Michele Whittaker BUG REPORT ID: BugID: 4592308 APPLIES TO: Hardware/Sun Fire /3800, Hardware/Sun Fire /4800, Hardware/Sun Fire /4810, Hardware/Sun Fire /6800 ATTACHMENTS:


Copyright (c) 1997-2003 Sun Microsystems, Inc.