SRDB ID   Synopsis   Date
45889   Sun Fire[TM] 3800-6800: Upgrade to firmware 5.13.x causes loss of network settings on the SC   17 Jul 2002

Status Issued

Description

In updating Sun Fire System Controllers to firmware revision 5.13.x, a number of reports have been received that after updating ScApp and RTOS, the SC reboots but the network settings on the SC are lost.

SOLUTION SUMMARY:

The issue has been root-caused and only affects System Controllers which currently run 5.11.x firmware or have been upgraded to 5.12.x from 5.11.x. A fix is in progress to resolve the issue. System Controllers which shipped from the factory with 5.12.x and higher are NOT affected.

While upgrading a System Controller:

1. Issue the flashupdate commands via the Serial Port and not an SC telnet session.

2. Copy down pertinent parameters before upgrading. This information includes output from:

Keywords: firmware, network, SC

INTERNAL SUMMARY: SUBMITTER: Michele Whittaker APPLIES TO: Hardware/Sun Fire /3800, Hardware/Sun Fire /4800, Hardware/Sun Fire /4810, Hardware/Sun Fire /6800 ATTACHMENTS: