SRDB ID | Synopsis | Date | ||
46701 | Sun StorEdge[TM] A3000: Symptom:Save Module Profile Blank Fields | 15 Nov 2002 |
Status | Issued |
Description |
If most fields are blank in a save_module_profile for
one of two controllers in a A3000/A3500.
Example: Controller A
Profile for sol_001
Host: sol
Controllers:
Name Serial Number Mode Logical Units
A 1T70917047 Offline 0
B (c2t4d0s0) 1T81309729 Active 7
Number of Drives = 35
Detailed Controller Information for sol_001
Parameters Controller A Controller B
(c2t4d0s0)
Board Name: Symbios Logic Series
3 RA
Board ID: 3621
Board Serial Number: 1T70917047 1T81309729
Product ID: RSM Array 2000
Product Serial Number: 1T81309729
Vendor ID: SYMBIOS
Date of Manufacture: 03/28/98
SCSI ID: Not Available 4
Boot Level: 02.05.06.32
Firmware Level: 02.05.06.32
Fibre Channel Level: -
Cache/Processor Size: 64/16 MB 64/16 MB
Cu has added a controller to a A3000/A35000.
However, customer has not used Recovery Guru to replace the controller.
In some cases a Board Serial Number will appear. This
number reflects the controller that had been replaced.
Cu should simply run RM6 gui and use the recovery gui
to REPLACE the controller. The gui should indicate a
failed controller to replace.
Follow the steps as given by RM6.
INTERNAL SUMMARY:
SUBMITTER: Robert Letteri APPLIES TO: Hardware/Disk Storage Subsystem/StorEdge Disk Array/StorEdge A3000, Hardware/Disk Storage Subsystem/StorEdge Disk Array/StorEdge A3500 ATTACHMENTS: