SRDB ID   Synopsis   Date
47298   Sun Fire[TM] 12K/15K: Addition of component to ASR blacklist failed: ecode=50000   7 Oct 2002

Status Issued

Description

The following error messages appears in the system controller messages file:

Mar 10 11:33:57 2002 orlocn01-sc0 esmd[506]: [1971 171363005960230 ERRSysControl.cc 3084] Addition of component to
ASR blacklist failed: ecode=50000                   

SOLUTION SUMMARY:

Explanation:

Generic Error 50000 indicates that "File open failed: file_name,ecode=error#".

Action:

The most likely cause of the ecode=5000 failure code is a permissions issue with the ASR blacklist file. Permissions for the file should be:

sms-svc> pwd 
/etc/opt/SUNWSMS/SMS1.2/config/asr 
sms-svc> ls -l 
total 0 
-rw-r--r--   1 sms-esmd bin            0 Jul 14 08:37 blacklist
                  

INTERNAL SUMMARY:

SUBMITTER: Joshua Freeman APPLIES TO: AFO Vertical Team Docs/HAS, Hardware/Sun Fire /15000 ATTACHMENTS:


Copyright (c) 1997-2003 Sun Microsystems, Inc.