SRDB ID   Synopsis   Date
47306   Sun Fire[TM] 12K/15K: esmd: board not thermcalled   7 Oct 2002

Status Issued

Description

When trying to power on a brand new expander, the following error message appears:

 esmd: board not thermcalled             

SOLUTION SUMMARY:

Explanation:

Thermcal config has not yet been run on the new expander. Unlike the E10K there is no thermcal_config command on the Sun Fire 15K. The expander is supposed to be thermcalled at the factory.

Action:

A new expander must be sent on site. In certain circumstances, however, PTS may be able to provide the SSE on site with the thermcal script to run on a case by case instance.

INTERNAL SUMMARY:

SUBMITTER: Joshua Freeman APPLIES TO: AFO Vertical Team Docs/HAS, Hardware/Sun Fire /15000 ATTACHMENTS:


Copyright (c) 1997-2003 Sun Microsystems, Inc.