SRDB ID | Synopsis | Date | ||
47321 | Sun Fire[TM] 12K/15K: WARNING: Component ID is up-version | 9 Oct 2002 |
Status | Issued |
Description |
The Sun Fire[TM] 12K/15K System Controller (SC) logs the following error messages:
WARNING: Component ID is up-version: Actual: 603D40FD for Man Ether Hub IO00 Assuming equivalent to: 403D40FD WARNING: Component ID is up-version: Actual: 603D40FD for Man Ether Hub IO01 Assuming equivalent to: 403D40FD WARNING: Component ID is up-version: Actual: 603D40FD for Man Ether Hub IO02 Assuming equivalent to: 403D40FD
SOLUTION SUMMARY:
Explanation:
From Rene Fennet CPRE:
This is a fairly new but known issue. A new version of the hub chip introduced in the system that needed to be done urgently due to short supply of the older types. This had to happen quickly so the software hasn't been updated (patched) yet. This will be done in the future but it hasn't got a very high priority because it doesn't affect the working of the system. Hence only the warning.
Action:
See Bug ID
INTERNAL SUMMARY:
SUBMITTER: Joshua Freeman BUG REPORT ID: 4649862 PATCH ID: 112488-04 APPLIES TO: AFO Vertical Team Docs/HAS, Hardware/Sun Fire /15000 ATTACHMENTS: