SRDB ID | Synopsis | Date | ||
47343 | Sun Fire[TM] 12K/15K: Dstop: Slot0 dtransid input parity error | 27 Nov 2002 |
Status | Issued |
Description |
- Problem Statement/Title: Dstop: Slot0 dtransid input parity error - Symptoms: 'wfail' output reports something similar to the following: 01 redxl> dumpf load dsmd.dstop.020509.1733.55 02 Created Thu May 9 17:33:57 2002 03 By hpost v. 1.2 Generic 112488-04 Mar 18 2002 14:43:00 executing as pid=6822 04 On ssc name = rasputin-sc0.SD_RASCAL.West.Sun.COM 05 Domain = 0=A Platform = rasputin 06 Boards in dump: master SC CPs/CSBs[1:0]: 3 07 EXB[17:0]: 12100 08 Slot0[17:0]: 12100 09 Slot1[17:0]: 12100 10 -D option, -d 11 "DSMD DomainStop Dump" 12 0 errors occurred while creating this dump. 13 redxl> wfail 14 SDI EX08/S0 Master_Stop_Status0[31:0] = D004000F 15 MStop0[3:0]: All SDI logic is DStopped + Recordstopped. 16 SDI EX08/S0 Dstop0[31:0] = 00818080 17 Dstop0[16]: D DARB texp requests all Dstop (M) 18 Dstop0[23]: D 1E SDI internal Slot0 port requested Dstop 19 SDI EX08/S0 Slot0_Error1[31:0] = 08008800 Mask = 31444EBF 20 S0Err1[27]: D 1E Slot0 dtransid input parity error (M) 21 slt0_{dtransidp,datareqin,datareqout,dstat[1:0],dtarg} = 10 22 slt0_dtransid[8:0] = 000 23 FAIL Slot SB8: Dstop/Rstop detected by SDI 24 Primary service FRU is Slot SB8. 25 Secondary service FRU is EXB EX8. 26 SDI EX13/S0: All SDI is DStopped and RStopped, requested by DARB. 27 SDI EX16/S0: All SDI is DStopped and RStopped, requested by DARB. 28 DARB C0: enabled ports (expanders) [17:0]: 16100 29 DARB C0: other darb req Dstop+Rstop for exps[17:0]: 00100 30 DARB C1: enabled ports (expanders) [17:0]: 16100 31 DARB C1: other darb req Dstop+Rstop for exps[17:0]: 00100
SOLUTION SUMMARY:
- Troubleshooting: The dump header tells us that this Dstop was generated by dsmd (lines 10,11) while a domain was active. This is also evident by the dumpf file name - dsmd.dstop files are created by dsmd as part of an ASR. Walking the error chain: - Master SDI on EX8 calls for Dstop as directed by itself (line 18) - Master SDI on EX8 detects a DTransID input parity error for Slot 0 (line 20). - SB8 is FAILed from the configuration (line 23) - SB8 and EX8 are named as primary and secondary FRUs (lines 24,25) The SDC on a L1 board and the SDI exchange DTransID and DTarg information. The data exchange is parity protected. Since these pathways cross an interconnect, a single FRU cannot be isolated. Suspect components ar SB8 and EX8. - Resolution: Replace SB8. If errors persist, replace EX8. - Summary of part number and patch ID's http://infoserver.central/data/syshbk/Devices/System_Board/SYSBD_SunFire_USIIICu.html http://infoserver.central/data/syshbk/Systems/SunFire15K/component.centerplane.html - References and bug IDs SunSolve Article 48122 SDI ASIC Specification - Additional background information: DTransIDs are used for arbitration, deriving data path steering, and data identification (tags). The SDC must request access to use the data bus to the SDI. When granted, the SDC supplies the target information and generates parity. The SDI receives the information and checks parity. A parity error constitutes a Dstop. The arbitration connections between the SDI and SDC on a Slot 0 board are as follows: slt0_datareqin_l Unidirectional SDC request to use bidirectional path slt0_datareqout_l High Priority request to SDC to get off the data path in 2 cycles slt0_data_l<1:0> Bidirectional data status (not part of arbitration) slt0_dtarg_l Bidirectional Read/Write bit (write operation when asserted) slt0_dtransid_l<8:0> Bidirectional data tag and arbitration steering information slt0_dataidp_l Unidirectional parity on above signals. Generated only by the SDC and sent to the SDI for checking In the case of a parity error, the wfail provides an indication of the faulty signal (line 21), but the overall diagnosis is as above. - Keywords 15K, 12K, SF15K, SF12K, Sun Fire 15K, Enterprise, Server, Sun Fire 12K, Slot0 dtransid input parity error, dstop
INTERNAL SUMMARY:
SUBMITTER: Joshua Freeman APPLIES TO: AFO Vertical Team Docs/HAS, Hardware/Sun Fire /15000, Hardware/Sun Fire /12000 ATTACHMENTS: