SRDB ID | Synopsis | Date | ||
47423 | Sun Fire[TM] 12K/15K: Level 64 HPOST error: Failed to read temperature point DMX0 | 23 Oct 2002 |
Status | Issued |
Description |
When we start the hpost Stress script "hpost -d A -pnone -l64 -v40 -Perr_print 64 -Pno_obp_handoff" from the EIS CD, we see in showlogs:
.....ERR DetectorT.cc 239] Failed to read temperature point DMX0, located on CP at CP0: ecode=145
In showenvironment we see also:
CP at CP0 dmx0 DMX0 Temp -- -- -- BAD
SOLUTION SUMMARY:
Explanation:
From Thomas Chalfant:
Likely this is a condition to ignore, assuming this doesn't occur repeatedly even when the SC is not busy running high level hposts.
Action:
Re-run the HPOST. This problem appears to be Bug ID 4632832 which will be fixed by SMS 1.3. It is fixed in SMS 1.2 by patch ID 112481-06 (The patch is, as of this writing, still unavailable).
INTERNAL SUMMARY:
SUBMITTER: Joshua Freeman APPLIES TO: AFO Vertical Team Docs/HAS, Hardware/Sun Fire /15000 ATTACHMENTS: