SRDB ID | Synopsis | Date | ||
47471 | Sun StorEdge[TM] 9900:Symptom:Command Device Type does not show Label Correctly in Format for 9900v System | 13 Nov 2002 |
Status | Issued |
Description |
As part of True Copy or Shadowimage Raid Manager CCI, the procedure requires a command device to be created.
Map a lun.
It is required that you make this device a"command device".
Forget to make it a "command device" in Storage Navigator.
On Solaris system issue "devfsadm"; see the lun.
Once labeled, it is missing the required "CM" in the label name, ex:
c2t0d0 <HITACHI - Open-3 - CVS - 0112 cyl...
So go back into Storage Navigator and select the mapped lun and make it a "command device".
devfsadm
The label is the same.
Remapping the same cu:ldev device to the lun will not clear the label.
SOLUTION SUMMARY:
Solution section
Two options:
1. after changing the device to "command device"
devfsadm
dd over the label for c2t0d0s2
format and type
2. choose another cu:ldev to map to lun
devfsadm
format label
now the label should say:
c2t0d0 <HITACHI - Open-3 - CVS - CM-0112 cyl...
^^
INTERNAL SUMMARY:
Internal Section
Public SRDBs, on occasion, may require Sun-internal information to be included. This section is designated for including such information as:
SUBMITTER: Saida Memon APPLIES TO: Hardware/Disk Storage Subsystem/StorEdge Disk Array/StorEdge 9900 ATTACHMENTS: