SRDB ID | Synopsis | Date | ||
48136 | Sun Fire[TM] 12K/15K: MAN Interface Mappings | 29 Oct 2002 |
Status | Issued |
Description |
- Problem Statement: Cheat Sheet: MAN Interface Mapping - Symptoms:
N/A
SOLUTION SUMMARY:
- Troubleshooting: The tables below translate a network interface to the physical piece of hardware. System Controller NICs Driver Inst Device Path Connects To... ------ ----------------------------------------- ----------------- hme0 /pci@1f,0/pci@1,1/ethernet@1,1 Top-most RJ 45 connector on SC hme1 /pci@1f,0/pci@1,1/ethernet@3,1 hme1 on other SC eri0 /pci@1f,0/pci@1/pci@1/pci@0/ethernet@0,1 eri0 on other SC eri1 /pci@1f,0/pci@1/pci@1/pci@0/ethernet@1,1 Bottom-most RJ 45 connector on SC eri2 /pci@1f,0/pci@1/pci@1/pci@2/ethernet@0,1 I/O board 0 eri3 /pci@1f,0/pci@1/pci@1/pci@2/ethernet@1,1 I/O board 1 eri4 /pci@1f,0/pci@1/pci@1/pci@2/ethernet@2,1 I/O board 2 eri5 /pci@1f,0/pci@1/pci@1/pci@2/ethernet@3,1 I/O board 3 eri6 /pci@1f,0/pci@1/pci@1/pci@2/ethernet@4,1 I/O board 4 eri7 /pci@1f,0/pci@1/pci@1/pci@2/ethernet@5,1 I/O board 5 eri8 /pci@1f,0/pci@1/pci@1/pci@2/ethernet@6,1 I/O board 6 eri9 /pci@1f,0/pci@1/pci@1/pci@2/ethernet@7,1 I/O board 7 eri10 /pci@1f,0/pci@1/pci@1/pci@2/ethernet@8,1 I/O board 8 eri11 /pci@1f,0/pci@1/pci@1/pci@3/ethernet@0,1 I/O board 9 eri12 /pci@1f,0/pci@1/pci@1/pci@3/ethernet@1,1 I/O board 10 eri13 /pci@1f,0/pci@1/pci@1/pci@3/ethernet@2,1 I/O board 11 eri14 /pci@1f,0/pci@1/pci@1/pci@3/ethernet@3,1 I/O board 12 eri15 /pci@1f,0/pci@1/pci@1/pci@3/ethernet@4,1 I/O board 13 eri16 /pci@1f,0/pci@1/pci@1/pci@3/ethernet@5,1 I/O board 14 eri17 /pci@1f,0/pci@1/pci@1/pci@3/ethernet@6,1 I/O board 15 eri18 /pci@1f,0/pci@1/pci@1/pci@3/ethernet@7,1 I/O board 16 eri19 /pci@1f,0/pci@1/pci@1/pci@3/ethernet@8,1 I/O board 17 Domain NICs To translate the MAN driver instance to a physical interface on a domain, the /etc/path_to_inst must be consulted. % grep eri /etc/path_to_inst "/pci@11c,700000/ethernet@3,1" 0 "eri" Using the PCI Bus Address, the translation can be completed using the table below. In this example, instance 0 is pci@11c. Thus, instance eri0 is physically located on I/O board 8. Device Path Connects To... ------------------------------ -------------- /pci@1c,700000/ethernet@3,1 I/O board 0 /pci@3c,700000/ethernet@3,1 I/O board 1 /pci@5c,700000/ethernet@3,1 I/O board 2 /pci@7c,700000/ethernet@3,1 I/O board 3 /pci@9c,700000/ethernet@3,1 I/O board 4 /pci@bc,700000/ethernet@3,1 I/O board 5 /pci@dc,700000/ethernet@3,1 I/O board 6 /pci@fc,700000/ethernet@3,1 I/O board 7 /pci@11c,700000/ethernet@3,1 I/O board 8 /pci@13c,700000/ethernet@3,1 I/O board 9 /pci@15c,700000/ethernet@3,1 I/O board 10 /pci@17c,700000/ethernet@3,1 I/O board 11 /pci@19c,700000/ethernet@3,1 I/O board 12 /pci@1bc,700000/ethernet@3,1 I/O board 13 /pci@1dc,700000/ethernet@3,1 I/O board 14 /pci@1fc,700000/ethernet@3,1 I/O board 15 /pci@21c,700000/ethernet@3,1 I/O board 16 /pci@23c,700000/ethernet@3,1 I/O board 17 - Resolution: N/A - Summary of part number and patch ID's N/A - References and bug IDs - Additional background information: - Meta-Data/Problem categorization: Product/Platform: SF12K/SF15K Category: - Keywords 15K, 12K, SF15K, SF12K, starcat, MAN Interface Mapping
INTERNAL SUMMARY:
SUBMITTER: Mike Cootware APPLIES TO: Hardware/Sun Fire /15000, Hardware/Sun Fire /12000 ATTACHMENTS: