SRDB ID   Synopsis   Date
48136   Sun Fire[TM] 12K/15K: MAN Interface Mappings   29 Oct 2002

Status Issued

Description
- Problem Statement:

Cheat Sheet: MAN Interface Mapping

- Symptoms:      

N/A

SOLUTION SUMMARY:
- Troubleshooting:

        The tables below translate a network interface to the physical 
        piece of hardware.

        System Controller NICs

           Driver
            Inst    Device Path                               Connects To...
           ------  ----------------------------------------- -----------------
           hme0    /pci@1f,0/pci@1,1/ethernet@1,1            Top-most RJ 45
                                                             connector on SC
           hme1    /pci@1f,0/pci@1,1/ethernet@3,1            hme1 on other SC
           eri0    /pci@1f,0/pci@1/pci@1/pci@0/ethernet@0,1  eri0 on other SC
           eri1    /pci@1f,0/pci@1/pci@1/pci@0/ethernet@1,1  Bottom-most RJ 45
                                                             connector on SC
           eri2    /pci@1f,0/pci@1/pci@1/pci@2/ethernet@0,1  I/O board 0
           eri3    /pci@1f,0/pci@1/pci@1/pci@2/ethernet@1,1  I/O board 1
           eri4    /pci@1f,0/pci@1/pci@1/pci@2/ethernet@2,1  I/O board 2
           eri5    /pci@1f,0/pci@1/pci@1/pci@2/ethernet@3,1  I/O board 3
           eri6    /pci@1f,0/pci@1/pci@1/pci@2/ethernet@4,1  I/O board 4
           eri7    /pci@1f,0/pci@1/pci@1/pci@2/ethernet@5,1  I/O board 5
           eri8    /pci@1f,0/pci@1/pci@1/pci@2/ethernet@6,1  I/O board 6
           eri9    /pci@1f,0/pci@1/pci@1/pci@2/ethernet@7,1  I/O board 7
           eri10   /pci@1f,0/pci@1/pci@1/pci@2/ethernet@8,1  I/O board 8
           eri11   /pci@1f,0/pci@1/pci@1/pci@3/ethernet@0,1  I/O board 9
           eri12   /pci@1f,0/pci@1/pci@1/pci@3/ethernet@1,1  I/O board 10
           eri13   /pci@1f,0/pci@1/pci@1/pci@3/ethernet@2,1  I/O board 11
           eri14   /pci@1f,0/pci@1/pci@1/pci@3/ethernet@3,1  I/O board 12
           eri15   /pci@1f,0/pci@1/pci@1/pci@3/ethernet@4,1  I/O board 13
           eri16   /pci@1f,0/pci@1/pci@1/pci@3/ethernet@5,1  I/O board 14
           eri17   /pci@1f,0/pci@1/pci@1/pci@3/ethernet@6,1  I/O board 15
           eri18   /pci@1f,0/pci@1/pci@1/pci@3/ethernet@7,1  I/O board 16
           eri19   /pci@1f,0/pci@1/pci@1/pci@3/ethernet@8,1  I/O board 17

        Domain NICs

        To translate the MAN driver instance to a physical interface on 
        a domain, the /etc/path_to_inst must be consulted.

           % grep eri /etc/path_to_inst                    
           "/pci@11c,700000/ethernet@3,1" 0 "eri" 

        Using the PCI Bus Address, the translation can be completed 
        using the table below. In this example, instance 0 is pci@11c. 
        Thus, instance eri0 is physically located on I/O board 8.

           Device Path                     Connects To...
           ------------------------------  --------------
           /pci@1c,700000/ethernet@3,1     I/O board 0
           /pci@3c,700000/ethernet@3,1     I/O board 1
           /pci@5c,700000/ethernet@3,1     I/O board 2
           /pci@7c,700000/ethernet@3,1     I/O board 3
           /pci@9c,700000/ethernet@3,1     I/O board 4
           /pci@bc,700000/ethernet@3,1     I/O board 5
           /pci@dc,700000/ethernet@3,1     I/O board 6
           /pci@fc,700000/ethernet@3,1     I/O board 7
           /pci@11c,700000/ethernet@3,1    I/O board 8
           /pci@13c,700000/ethernet@3,1    I/O board 9
           /pci@15c,700000/ethernet@3,1    I/O board 10
           /pci@17c,700000/ethernet@3,1    I/O board 11
           /pci@19c,700000/ethernet@3,1    I/O board 12
           /pci@1bc,700000/ethernet@3,1    I/O board 13
           /pci@1dc,700000/ethernet@3,1    I/O board 14
           /pci@1fc,700000/ethernet@3,1    I/O board 15
           /pci@21c,700000/ethernet@3,1    I/O board 16
           /pci@23c,700000/ethernet@3,1    I/O board 17

- Resolution:

        N/A

- Summary of part number and patch ID's 

        N/A

- References and bug IDs


- Additional background information:

- Meta-Data/Problem categorization:

Product/Platform:  SF12K/SF15K
Category:

- Keywords

15K, 12K, SF15K, SF12K, starcat, MAN Interface Mapping
            

INTERNAL SUMMARY:

SUBMITTER: Mike Cootware APPLIES TO: Hardware/Sun Fire /15000, Hardware/Sun Fire /12000 ATTACHMENTS:


Copyright (c) 1997-2003 Sun Microsystems, Inc.