SRDB ID | Synopsis | Date | ||
48147 | Sun Fire[TM] 15K: Low System Memory Causes SC Failover | 30 Oct 2002 |
Status | Issued |
Description |
- Problem Statement: Main SC fails over to spare SC due to low system memory. - Symptoms: Messages from Main SC: Jun 28 11:25:50 2002 v4u-15ka-sc1 fomd[347]: [8567 2220835155213 NOTICE Failover Mgr.cc 1782] Failing over to the spare SC because of the following faults on the main SC: Low System Memory Messages from Spare SC: Jun 28 11:26:37 2002 v4u-15ka-sc0 fomd[378]: [8573 632701993069 NOTICE FailoverM gr.cc 2010] Taking over the main role because the remote SC (current Main) has a fault - Low System Memory
SOLUTION SUMMARY:
- Troubleshooting: Display your swap devices: v4u-15ka-sc1:sms-svc:5> swap -l swapfile dev swaplo blocks free /dev/dsk/c0t3d0s1 32,25 16 263856 263856 Take the number under the blocks column * 512. For example: 263856*512=135,094,272 In this case, there is approximately 135 megabytes of swap. There must be at least 2 gigabytes of swap. - Resolution: Add swap space to your existing swap space to total at least 2 gigabytes. NOTE: Verify BOTH the main & spare SC have at least 2 gigabytes of swap space. - Summary of part number and patch ID's - References and bug IDs FIN #: I0748-1 Sun Fire 15K System Controller should be configured with at least 2 Gbytes swap space. - Additional background information - Meta-Data/Problem categorization: Product/Platform: SF15K Category: - Keywords low system memory failover failing over swap
INTERNAL SUMMARY:
SUBMITTER: Rob Romack APPLIES TO: Hardware/Sun Fire /15000 ATTACHMENTS: