SRDB ID | Synopsis | Date | ||
48152 | Sun Fire[TM] 15K: HPOST check fails: BBC reset status does not show XIR | 30 Oct 2002 |
Status | Issued |
Description |
- Problem Statement: HPOST check fails: BBC reset status does not show XIR issued - Symptoms:
ERR: xcp_send_xir_to_port() and lpost_xir_proc_for_reinsertion() A. 'setkeyswitch on' hpost (any level) testing intermittently will fail with the following error: stage exp_lpost: Domain-level board and system tests... ERR: xcp_send_xir_to_port(): BBC SB6/BB0 reset status does not show XIR issued for Port SB6/P0. ERR: BBC SB6/BB0 reset status: 00001000 mask: 00000008 lpost_xir_proc_for_reinsertion(): Attempt to send XIR to Proc SB6/P0 failed
SOLUTION SUMMARY:
- Troubleshooting: A. This hpost failure occurs intermittently. Running the setkeyswitch operation a second time will normally succeed. B. The problem can be reported against different processors in the domain. C. The failure surfaces after installing SMS 1.2 patch 112488-05 or greater and when the LPOST version is 5.13.0 or less. - Resolution: A. Problem is corrected in LPOST version 5.13.1 (or higher) which is provided by SMS 1.2 patch 112829-03. You must flashupdate the CPU fproms on all system boards in the domain. See the special instructions in the patch README and the flashupdate man page for details. - Summary of part number and patch ID's LPOST version 5.13.1 SMS 1.2 patch 112829-03 - References and bug IDs4688062 - Additional background information: Patch112488-05 modified Sun Fire 15K hpost to use XIR in a number of places where safari reset had previously been used. This turns out to be the fault of save_reset_reason() in the firmware, which clears the reset status register after saving the reason. This means the sender of the reset is denied access to important status which adversely affects diagnosability. - Meta-Data/Problem categorization: Product/Platform: SF15K Category: - Keywords xcp_send_xir_to_port lpost_xir_proc_for_reinsertion BBC reset XIR
INTERNAL SUMMARY:
SUBMITTER: Gino Valencia BUG REPORT ID: 4688062 PATCH ID: 112488-05 APPLIES TO: Hardware/Sun Fire /15000 ATTACHMENTS: