SRDB ID | Synopsis | Date | ||
48185 | Sun Fire[TM] 12K/15K: Interrupt not serviced messages on System Controller | 30 Oct 2002 |
Status | Issued |
Description |
- Problem Statement/Title: SF15K Troubleshooting Article: Interrupt not serviced messages on System Controller - Symptoms: Warning messages in /var/adm/messages file on system controller (SC). Example : messages.3:Jun 4 14:11:18 l82ba249 unix: [ID 882636 kern.warning] WARNING: interrupt level 9 not serviced messages.3:Jun 4 14:11:45 l82ba249 unix: [ID 882636 kern.warning] WARNING: interrupt level 12 not serviced messages.3:Jun 4 14:11:48 l82ba249 unix: [ID 882636 kern.warning] WARNING: interrupt level 12 not serviced
SOLUTION SUMMARY:
- Troubleshooting: Examine /var/adm/messages file to see above error messages. "interrupt level n not serviced" means an interrupt was posted, but there wasn't a device to claim it. The error is generated when the interrupt handlers check the hardware state and decide that the hardware does not indicate an interrupt to be handled. The standard system controller is configured for interrupt levels 6, 9, 12 and 15. Interrupt Level Device 4 scsi 6 network (e.g. ethernet) 9 gchip or echip 12(Hex c) ebus serial driver 15(Hex e) ebus (power and i2c) As of this writing, "not serviced" messages for interrupts 4 and 15 have not been seen in any system message files. Interrupt level 6 (network) error has been addressed by the latest eri driver in Solaris[TM] 5.8 release. Interrupt level 9 (gchip) error is reported in bug #4725348, but no root cause has been found. Interrupt level 12 (Serial connection) errors are noticed often. You may look at the console log or /var/adm/messages to see any messages reported with the serial line connection. Please report to CPRE if you see any errors pointing to interrupt level 15. - Resolution: No action is required as these messages are not a cause of any failures. You may check the other errors in messages file to see if there is problem on the bus or network. In the current system controller with the standard configuration, these errors can be ignored. - Summary of part number and patch ID's None - References and bug IDs bugID #4725348 - Additional background information: None - Meta-Data/Problem categorization: Product/Platform: SF12K/SF15K Category: - Keywords interrupt level messages starcat SF12K SF15K
INTERNAL SUMMARY:
SUBMITTER: Vasant Butala BUG REPORT ID: 4725348 APPLIES TO: Hardware/Sun Fire /15000, Hardware/Sun Fire /12000 ATTACHMENTS: