SRDB ID   Synopsis   Date
48256   Sun Blade [TM] 100 systems may not auto-restart after a power failure.   29 Oct 2002

Status Issued

Description

Some Sun Blade 100 systems may fail to automatically restart subsequent to site power failures and resumption. (AC power cycling) The systems then must be re-started manually.

SOLUTION SUMMARY:

The problem lies within the power management unit (PMU) circuitry on the system board, which is responsible for latching the current state of power - standby or on. PMU register values were being intermittently corrupted during the power cycle event. The system board PMU circuitry has been modified.

Upon failure, replace:

375-0096-01 with 375-3106-01

375-3061-01 with 375-3106-01

375-3092-01 with 375-3106-01

375-3123-01 with 375-3106-01

INTERNAL SUMMARY:

Internal Section

alicia.brown@sun.com

Please reference internal FCO A0204-1

SUBMITTER: Alicia Brown APPLIES TO: AFO Vertical Team Docs/Hardware ATTACHMENTS:


Copyright (c) 1997-2003 Sun Microsystems, Inc.