SM81 SuperSPARC II Module

SS1000
Option 1177

501-3033
85MHz

Notes

  1. The minimum operating system is Solaris 2.4 and Patch >=101945-35.
  2. Patch 101945-35 enables the Multiple Command Mode.
  3. Solaris 2.4 requires Patch >=102001-08 if SunFastEthernet is installed.
  4. SS1000 Boot PROM 2.23 is required on all system boards.
  5. Mixing different module types is not supported.
  6. The SS1000 requires Left/Right Side Panel 330-1869.
  7. Side Panel 330-1869 is used on systems produced after July 1995.
  8. The maximum XDBus speed of the MXCC is 50MHz.
  9. The 15A Fuse at F0600 is not field replaceable.

References

  1. SuperSPARC Module Installation Guide, 802-1372.
  2. SS1000 and SS1000E Side Vent Product Note, 802-2896.
  3. SuperSPARC Module Product Note, 801-5015.

SM81 SuperSPARC II Module

SS1000
Option 1177

501-2953
85MHz

Notes

  1. The minimum operating system is Solaris 2.4 and Patch >=101945-35.
  2. Patch 101945-35 enables the Multiple Command Mode.
  3. Solaris 2.4 requires Patch >=102001-08 if SunFastEthernet is installed.
  4. SS1000 Boot PROM 2.23 is required on all system boards.
  5. Mixing different module types is not supported.
  6. The SS1000 requires Left/Right Side Panel 330-1869.
  7. Side Panel 330-1869 is used on systems produced after July 1995.
  8. The maximum XDBus speed of the MXCC is 50MHz.
  9. The 15A Fuse at F0600 is not field replaceable.

References

  1. SuperSPARC Module Installation Guide, 802-1372.
  2. SS1000 and SS1000E Side Vent Product Note, 802-2896.
  3. SuperSPARC Module Product Note, 801-5015.

SM81 SuperSPARC II Module

SS1000
Option 1177

501-4810
85MHz

Notes

  1. The minimum operating system is Solaris 2.4 and Patch >=101945-35.
  2. Patch 101945-35 enables the Multiple Command Mode.
  3. Solaris 2.4 requires Patch >=102001-08 if SunFastEthernet is installed.
  4. SS1000 Boot PROM 2.23 is required on all system boards.
  5. Mixing different module types is not supported.
  6. The SS1000 requires Left/Right Side Panel 330-1869.
  7. Side Panel 330-1869 is used on systems produced after July 1995.
  8. The maximum XDBus speed of the MXCC is 50MHz.
  9. The 15A Fuse at F0600 is not field replaceable.

References

  1. SuperSPARC Module Installation Guide, 802-1372.
  2. SS1000 and SS1000E Side Vent Product Note, 802-2896.
  3. SuperSPARC Module Product Note, 801-5015.