Sun Microsystems, Inc.
spacer spacer
spacer   Sun System Handbook Home | Systems | Components | General Info | Search | Feedback 
spacer
black dot
 
black fade
 

400MHz UltraSPARC II Module

E3000 / E4000 / E5000 / E3500 / E4500 / E5500

Option 2570

501-4995
4MB Cache Sapphire-Black

Notes

  1. The minimum operating system is 2.5.1 HW: 11/97 or 2.6 HW: 3/98.
  2. Solaris 2.5.1 patches >=103640-06 are required.
  3. OBP 3.2 Version 18 is required.
  4. Mixing module cache sizes on a single board requires OBP >=3.2.21.
  5. Mixing module speeds within a system is not supported.
  6. The 8-slot Gigaplane operating at 100MHz with seven CPU/Memory boards and 400MHz modules does not support N+1 Power.

Compatibility Notes

  1. Clock 501-2975 is not supported.
  2. This module requires 100MHz CPU/Memory and I/O boards.
  3. The E3x00 supports Clocks 501-4286, 501-4946, and 501-5365.
  4. The E4x00 and E5x00 do not support Clock 501-4286.
  5. The E4x00 and E5x00 support Clocks 501-4946 and 501-5365.
  6. The E4000 and E5000 require a 100MHz Centerplane upgrade.
  7. This module is not supported in the E6000 or E6500.

Reference

CPU Module Installation Guide, 806-0960.

400MHz UltraSPARC II Module

E10000

Option 2570

501-4995
4MB Cache Sapphire-Black

Notes

  1. The minimum operating system is 2.5.1 HW: 11/97 or 2.6 HW: 3/98.
  2. Mixing module speeds within a system is supported.
  3. A minimum of one processor per System Board is required.
  4. Set the clock multiplier to 2:1 with the command:
    sys_clock -p two-to-one -s -i 100000000
  5. System Boards 501-4347, 501-4786, and 501-4903 are not compatible with the 400MHz UltraSPARC module.
  6. System Boards 501-5240, 501-5278, 501-5279, and 501-5693 are compatible with the 400MHz UltraSPARC module.

Reference:

System Board Installation and Configuration Guide, 805-7189.


400MHz UltraSPARC II Module

E3000 / E4000 / E5000 / E3500 / E4500 / E5500

Option 2570

501-5425
4MB Cache Sapphire-Black

Notes

  1. The minimum operating system is 2.5.1 HW: 11/97 or 2.6 HW: 3/98.
  2. Solaris 2.5.1 patches >=103640-06 are required.
  3. OBP 3.2 Version 18 is required.
  4. Mixing module cache sizes on a single board requires OBP >=3.2.21.
  5. Mixing module speeds within a system is not supported.
  6. The 8-slot Gigaplane operating at 100MHz with seven CPU/Memory boards and 400MHz modules does not support N+1 Power.

Compatibility Notes

  1. Clock 501-2975 is not supported.
  2. This module requires 100MHz CPU/Memory and I/O boards.
  3. The E3x00 supports Clocks 501-4286, 501-4946, and 501-5365.
  4. The E4x00 and E5x00 do not support Clock 501-4286.
  5. The E4x00 and E5x00 support Clocks 501-4946 and 501-5365.
  6. The E4000 and E5000 require a 100MHz Centerplane upgrade.
  7. This module is not supported in the E6000 or E6500.

Reference

CPU Module Installation Guide, 806-0960.

400MHz UltraSPARC II Module

E10000

Option 2570

501-5425
4MB Cache Sapphire-Black

Notes

  1. The minimum operating system is 2.5.1 HW: 11/97 or 2.6 HW: 3/98.
  2. Mixing module speeds within a system is supported.
  3. A minimum of one processor per System Board is required.
  4. Set the clock multiplier to 2:1 with the command:
    sys_clock -p two-to-one -s -i 100000000
  5. System Boards 501-4347, 501-4786, and 501-4903 are not compatible with the 400MHz UltraSPARC module.
  6. System Boards 501-5240, 501-5278, 501-5279, and 501-5693 are compatible with the 400MHz UltraSPARC module.

Reference:

System Board Installation and Configuration Guide, 805-7189.


400MHz UltraSPARC II Module

E3000 / E4000 / E5000 / E3500 / E4500 / E5500

Option 2570

501-5585
4MB Cache Sapphire-Black

Notes

  1. The minimum operating system is 2.5.1 HW: 11/97 or 2.6 HW: 3/98.
  2. Solaris 2.5.1 patches >=103640-06 are required.
  3. OBP 3.2 Version 18 is required.
  4. Mixing module cache sizes on a single board requires OBP >=3.2.21.
  5. Mixing module speeds within a system is not supported.
  6. The 8-slot Gigaplane operating at 100MHz with seven CPU/Memory boards and 400MHz modules does not support N+1 Power.

Compatibility Notes

  1. Clock 501-2975 is not supported.
  2. This module requires 100MHz CPU/Memory and I/O boards.
  3. The E3x00 supports Clocks 501-4286, 501-4946, and 501-5365.
  4. The E4x00 and E5x00 do not support Clock 501-4286.
  5. The E4x00 and E5x00 support Clocks 501-4946 and 501-5365.
  6. The E4000 and E5000 require a 100MHz Centerplane upgrade.
  7. This module is not supported in the E6000 or E6500.

Reference

CPU Module Installation Guide, 806-0960.

400MHz UltraSPARC II Module

E10000

Option 2570

501-5585
4MB Cache Sapphire-Black

Notes

  1. The minimum operating system is 2.5.1 HW: 11/97 or 2.6 HW: 3/98.
  2. Mixing module speeds within a system is supported.
  3. A minimum of one processor per System Board is required.
  4. Set the clock multiplier to 2:1 with the command:
    sys_clock -p two-to-one -s -i 100000000
  5. System Boards 501-4347, 501-4786, and 501-4903 are not compatible with the 400MHz UltraSPARC module.
  6. System Boards 501-5240, 501-5278, 501-5279, and 501-5693 are compatible with the 400MHz UltraSPARC module.

Reference:

System Board Installation and Configuration Guide, 805-7189.


400MHz UltraSPARC II Module

E3000 / E4000 / E5000 / E6000
E3500 / E4500 / E5500 / E6500

Option 2580

501-5235
8MB Cache Sapphire-Black

Notes

  1. The minimum operating system is 2.5.1 HW: 11/97 or 2.6 HW: 3/98.
  2. Solaris 2.5.1 patch >=103640-27 and 2.6 patch >=105181-14 are required.
  3. OBP 3.2 Version 21 is required. OBP 3.2 Version 24 is recommended.
  4. Use the limit-ecache-size OBP command before installing Solaris 2.5.1 and before booting Solaris 2.5.1 without patch 103640-27.
  5. Use the limit-ecache-size OBP command before installing Solaris 2.6 and before booting Solaris 2.6 without patch 105181-14.
  6. Mixing module speeds within a system is not supported.
  7. The 8-slot Gigaplane operating at 100MHz with seven CPU/Memory boards and 400MHz modules does not support N+1 Power.

Compatibility Notes

  1. Clock 501-2975 is not supported.
  2. The E6000 and E6500 require Clock 501-5365 for a 5:1 clock ratio.
  3. The E3x00, E4x00, and E5x00 require Clock 501-5365 for a 5:1 clock ratio if 84MHz system boards are installed.
  4. Clock 501-4286 or 501-4946 is supported in the E3x00, E4x00, and E5x00 if the centerplane and all system boards are 100MHz.
  5. Clock 501-5365 is supported if 84MHz or 100MHz system boards are installed in the E3x00, E4x00, and E5x00.

Reference

CPU Module Installation Guide, 806-0960.

400MHz UltraSPARC II Module

E10000

Option 2580

501-5235
8MB Cache Sapphire-Black

Notes

  1. Mixing module speeds within a system is supported.
  2. A minimum of one processor per System Board is required.
  3. Set the clock multiplier to 2:1 with the command:
    sys_clock -p two-to-one -s -i 100000000
  4. System Boards 501-4347, 501-4786, and 501-4903 are not compatible with the 400MHz UltraSPARC module.
  5. System Boards 501-5240, 501-5278, 501-5279, and 501-5693 are compatible with the 400MHz UltraSPARC module.

Reference:

System Board Installation and Configuration Guide, 805-7189.


400MHz UltraSPARC II Module

E3000 / E4000 / E5000 / E6000
E3500 / E4500 / E5500 / E6500

Option 2580

501-5661
8MB Cache Sapphire-Black

Notes

  1. The minimum operating system is 2.5.1 HW: 11/97 or 2.6 HW: 3/98.
  2. Solaris 2.5.1 patch >=103640-27 and 2.6 patch >=105181-14 are required.
  3. OBP 3.2 Version 21 is required. OBP 3.2 Version 24 is recommended.
  4. Use the limit-ecache-size OBP command before installing Solaris 2.5.1 and before booting Solaris 2.5.1 without patch 103640-27.
  5. Use the limit-ecache-size OBP command before installing Solaris 2.6 and before booting Solaris 2.6 without patch 105181-14.
  6. Mixing module speeds within a system is not supported.
  7. The 8-slot Gigaplane operating at 100MHz with seven CPU/Memory boards and 400MHz modules does not support N+1 Power.

Compatibility Notes

  1. Clock 501-2975 is not supported.
  2. The E6000 and E6500 require Clock 501-5365 for a 5:1 clock ratio.
  3. The E3x00, E4x00, and E5x00 require Clock 501-5365 for a 5:1 clock ratio if 84MHz system boards are installed.
  4. Clock 501-4286 or 501-4946 is supported in the E3x00, E4x00, and E5x00 if the centerplane and all system boards are 100MHz.
  5. Clock 501-5365 is supported if 84MHz or 100MHz system boards are installed in the E3x00, E4x00, and E5x00.

Reference

CPU Module Installation Guide, 806-0960.

400MHz UltraSPARC II Module

E10000

Option 2580

501-5661
8MB Cache Sapphire-Black

Notes

  1. Mixing module speeds within a system is supported.
  2. A minimum of one processor per System Board is required.
  3. Set the clock multiplier to 2:1 with the command:
    sys_clock -p two-to-one -s -i 100000000
  4. System Boards 501-4347, 501-4786, and 501-4903 are not compatible with the 400MHz UltraSPARC module.
  5. System Boards 501-5240, 501-5278, 501-5279, and 501-5693 are compatible with the 400MHz UltraSPARC module.

Reference:

System Board Installation and Configuration Guide, 805-7189.


400MHz UltraSPARC II Module

E3000 / E4000 / E5000 / E6000
E3500 / E4500 / E5500 / E6500

Option 2580

501-5762
8MB Cache Sapphire-Black

Notes

  1. The minimum operating system is 2.5.1 HW: 11/97 or 2.6 HW: 3/98.
  2. Solaris 2.5.1 patch >=103640-27 and 2.6 patch >=105181-14 are required.
  3. OBP 3.2 Version 21 is required. OBP 3.2 Version 24 is recommended.
  4. Use the limit-ecache-size OBP command before installing Solaris 2.5.1 and before booting Solaris 2.5.1 without patch 103640-27.
  5. Use the limit-ecache-size OBP command before installing Solaris 2.6 and before booting Solaris 2.6 without patch 105181-14.
  6. Mixing module speeds within a system is not supported.
  7. The 8-slot Gigaplane operating at 100MHz with seven CPU/Memory boards and 400MHz modules does not support N+1 Power.
  8. For more information on 501-5762, see ECO WO_16898.

Compatibility Notes

  1. Clock 501-2975 is not supported.
  2. The E6000 and E6500 require Clock 501-5365 for a 5:1 clock ratio.
  3. The E3x00, E4x00, and E5x00 require Clock 501-5365 for a 5:1 clock ratio if 84MHz system boards are installed.
  4. Clock 501-4286 or 501-4946 is supported in the E3x00, E4x00, and E5x00 if the centerplane and all system boards are 100MHz.
  5. Clock 501-5365 is supported if 84MHz or 100MHz system boards are installed in the E3x00, E4x00, and E5x00.

Reference

CPU Module Installation Guide, 806-0960.

400MHz UltraSPARC II Module

E10000

Option 2580

501-5762
8MB Cache Sapphire-Black

Notes

  1. Mixing module speeds within a system is supported.
  2. A minimum of one processor per System Board is required.
  3. Set the clock multiplier to 2:1 with the command:
    sys_clock -p two-to-one -s -i 100000000
  4. System Boards 501-4347, 501-4786, and 501-4903 are not compatible with the 400MHz UltraSPARC module.
  5. System Boards 501-5240, 501-5278, 501-5279, and 501-5693 are compatible with the 400MHz UltraSPARC module.
  6. For more information on 501-5762, see ECO WO_16898.

Reference:

System Board Installation and Configuration Guide, 805-7189.


400MHz UltraSPARC II Module

E3000 / E4000 / E5000 / E6000
E3500 / E4500 / E5500 / E6500

Option 2580

501-5838
8MB Cache Sapphire-Black
IBM Sombra Mirrored Data SRAM

Notes

  1. The minimum operating system is 2.5.1 HW: 11/97 or 2.6 HW: 3/98.
  2. Solaris 2.5.1 patch >=103640-27 and 2.6 patch >=105181-14 are required.
  3. OBP 3.2 Version 21 is required. OBP 3.2 Version 24 is recommended.
  4. Use the limit-ecache-size OBP command before installing Solaris 2.5.1 and before booting Solaris 2.5.1 without patch 103640-27.
  5. Use the limit-ecache-size OBP command before installing Solaris 2.6 and before booting Solaris 2.6 without patch 105181-14.
  6. Mixing module speeds within a system is not supported.
  7. The 8-slot Gigaplane operating at 100MHz with seven CPU/Memory boards and 400MHz modules does not support N+1 Power.

Compatibility Notes

  1. Clock 501-2975 is not supported.
  2. The E6000 and E6500 require Clock 501-5365 for a 5:1 clock ratio.
  3. The E3x00, E4x00, and E5x00 require Clock 501-5365 for a 5:1 clock ratio if 84MHz system boards are installed.
  4. Clock 501-4286 or 501-4946 is supported in the E3x00, E4x00, and E5x00 if the centerplane and all system boards are 100MHz.
  5. Clock 501-5365 is supported if 84MHz or 100MHz system boards are installed in the E3x00, E4x00, and E5x00.

Reference

CPU Module Installation Guide, 806-0960.

400MHz UltraSPARC II Module

E10000

Option 2580

501-5838
8MB Cache Sapphire-Black
IBM Sombra Mirrored Data SRAM

Notes

  1. The minimum SSP release is 3.3.
  2. Patch >=108885-09 (SSP 3.3) or >=110304-05 (SSP 3.4) is required.
    (No patching is required for SSP 3.5.)
  3. Mixing module speeds within a system is supported.
  4. A minimum of one processor per System Board is required.
  5. Set the clock multiplier to 2:1 with the command:
    sys_clock -p two-to-one -s -i 100000000
  6. System Boards 501-4347, 501-4786, and 501-4903 are not compatible with the 400MHz UltraSPARC module.
  7. System Boards 501-5240, 501-5278, 501-5279, and 501-5693 are compatible with the 400MHz UltraSPARC module.

Reference:

System Board Installation and Configuration Guide, 805-7189.


400MHz UltraSPARC II Module

E3000 / E4000 / E5000 / E6000
E3500 / E4500 / E5500 / E6500

501-6008
8MB Cache Sapphire-Black
IBM Sombra Mirrored Data SRAM

Notes

  1. The minimum operating system is 2.5.1 HW: 11/97 or 2.6 HW: 3/98.
  2. Solaris 2.5.1 patch >=103640-27 and 2.6 patch >=105181-14 are require d.
  3. OBP 3.2 Version 21 is required. OBP 3.2 Version 29 is recommended.
  4. Use the limit-ecache-size OBP command before installing Solaris 2.5.1 and before booting Solaris 2.5.1 without patch 103640-27.
  5. Use the limit-ecache-size OBP command before installing Solaris 2.6 and before booting Solaris 2.6 without patch 105181-14.
  6. Mixing module speeds within a system is not supported.
  7. The 8-slot Gigaplane operating at 100MHz with seven CPU/Memory boards and 400MHz modules does not support N+1 Power.

Compatibility Notes

  1. Clock 501-2975 is not supported.
  2. The E6000 and E6500 require Clock 501-5365 for a 5:1 clock ratio.
  3. The E3x00, E4x00, and E5x00 require Clock 501-5365 for a 5:1 clock ratio if 84MHz system boards are installed.
  4. Clock 501-4286 or 501-4946 is supported in the E3x00, E4x00, and E5x00 if the centerplane and all system boards are 100MHz.
  5. Clock 501-5365 is supported if 84MHz or 100MHz system boards are installed in the E3x00, E4x00, and E5x00.

Reference

CPU Module Installation Guide, 806-0960.

400MHz UltraSPARC II Module

E10000

501-6008
8MB Cache Sapphire-Black
IBM Sombra Mirrored Data SRAM

Notes

  1. The minimum SSP release is 3.3.
  2. Patch >=108885-09 (SSP 3.3) or >=110304-05 (SSP 3.4) is required.
    (No patching is required for SSP 3.5.)
  3. Mixing module speeds within a system is supported.
  4. A minimum of one processor per System Board is required.
  5. Set the clock multiplier to 2:1 with the command:
    sys_clock -p two-to-one -s -i 100000000
  6. System Boards 501-4347, 501-4786, and 501-4903 are not compatible with the 400MHz UltraSPARC module.
  7. System Boards 501-5240, 501-5278, 501-5279, and 501-5693 are compatible with the 400MHz UltraSPARC module.

Reference:

System Board Installation and Configuration Guide, 805-7189.


400MHz UltraSPARC II Module

E3000 / E4000 / E5000 / E6000
E3500 / E4500 / E5500 / E6500

Option 2580

501-6009
8MB Cache Sapphire-Black
IBM Sombra Mirrored Data SRAM
IBM Mirrored Tag SRAM

Notes

  1. The minimum operating system is 2.5.1 HW: 11/97 or 2.6 HW: 3/98.
  2. Solaris 2.5.1 patch >=103640-27 and 2.6 patch >=105181-14 are require d.
  3. OBP 3.2 Version 21 is required. OBP 3.2 Version 29 is recommended.
  4. Use the limit-ecache-size OBP command before installing Solaris 2.5.1 and before booting Solaris 2.5.1 without patch 103640-27.
  5. Use the limit-ecache-size OBP command before installing Solaris 2.6 and before booting Solaris 2.6 without patch 105181-14.
  6. Mixing module speeds within a system is not supported.
  7. The 8-slot Gigaplane operating at 100MHz with seven CPU/Memory boards and 400MHz modules does not support N+1 Power.

Compatibility Notes

  1. Clock 501-2975 is not supported.
  2. The E6000 and E6500 require Clock 501-5365 for a 5:1 clock ratio.
  3. The E3x00, E4x00, and E5x00 require Clock 501-5365 for a 5:1 clock ratio if 84MHz system boards are installed.
  4. Clock 501-4286 or 501-4946 is supported in the E3x00, E4x00, and E5x00 if the centerplane and all system boards are 100MHz.
  5. Clock 501-5365 is supported if 84MHz or 100MHz system boards are installed in the E3x00, E4x00, and E5x00.

Reference

CPU Module Installation Guide, 806-0960.

400MHz UltraSPARC II Module

E10000

Option 2580

501-6009
8MB Cache Sapphire-Black
IBM Sombra Mirrored Data SRAM
IBM Mirrored Tag SRAM

Notes

  1. The minimum SSP release is 3.3.
  2. Patch >=108885-09 (SSP 3.3) or >=110304-05 (SSP 3.4) is required.
    (No patching is required for SSP 3.5.)
  3. Mixing module speeds within a system is supported.
  4. A minimum of one processor per System Board is required.
  5. Set the clock multiplier to 2:1 with the command:
    sys_clock -p two-to-one -s -i 100000000
  6. System Boards 501-4347, 501-4786, and 501-4903 are not compatible with the 400MHz UltraSPARC module.
  7. System Boards 501-5240, 501-5278, 501-5279, and 501-5693 are compatible with the 400MHz UltraSPARC module.

Reference:

System Board Installation and Configuration Guide, 805-7189.


400MHz UltraSPARC II Module

E3000 / E4000 / E5000 / E6000
E3500 / E4500 / E5500 / E6500

Option 2580

501-5814
8MB Cache Blaze
IBM Sombra Mirrored Data SRAM
IBM Mirrored Tag SRAM

Notes

  1. The minimum operating system is 2.5.1 HW: 11/97 or 2.6 HW: 3/98.
  2. Solaris 2.5.1 patch >=103640-27 and 2.6 patch >=105181-14 are required.
  3. OBP 3.2 Version 21 is required. OBP 3.2 Version 29 is recommended.
  4. Use the limit-ecache-size OBP command before installing Solaris 2.5.1 and before booting Solaris 2.5.1 without patch 103640-27.
  5. Use the limit-ecache-size OBP command before installing Solaris 2.6 and before booting Solaris 2.6 without patch 105181-14.
  6. Mixing module speeds within a system is not supported.
  7. The 8-slot Gigaplane operating at 100MHz with seven CPU/Memory boards and 400MHz modules does not support N+1 Power.

Compatibility Notes

  1. Clock 501-2975 is not supported.
  2. The E6000 and E6500 require Clock 501-5365 for a 5:1 clock ratio.
  3. The E3x00, E4x00, and E5x00 require Clock 501-5365 for a 5:1 clock ratio if 84MHz system boards are installed.
  4. Clock 501-4286 or 501-4946 is supported in the E3x00, E4x00, and E5x00 if the centerplane and all system boards are 100MHz.
  5. Clock 501-5365 is supported if 84MHz or 100MHz system boards are installed in the E3x00, E4x00, and E5x00.

Reference

CPU Module Installation Guide, 806-0960.

400MHz UltraSPARC II Module

E10000

Option 2580

501-5814
8MB Cache Blaze
IBM Sombra Mirrored Data SRAM
IBM Mirrored Tag SRAM

Notes

  1. The minimum SSP release is 3.3.
  2. Patch >=108885-09 (SSP 3.3) or >=110304-05 (SSP 3.4) is required.
    (No patching is required for SSP 3.5.)
  3. Mixing module speeds within a system is supported.
  4. A minimum of one processor per System Board is required.
  5. Set the clock multiplier to 2:1 with the command:
    sys_clock -p two-to-one -s -i 100000000
  6. System Boards 501-4347, 501-4786, and 501-4903 are not compatible with the 400MHz UltraSPARC module.
  7. System Boards 501-5240, 501-5278, 501-5279, and 501-5693 are compatible with the 400MHz UltraSPARC module.

Reference:

System Board Installation and Configuration Guide, 805-7189.


400MHz UltraSPARC II Module

E3000 / E4000 / E5000 / E6000
E3500 / E4500 / E5500 / E6500

Option 2580

501-5815
8MB Cache Blaze
Sony Espejo Mirrored Data SRAM
Sony Mirrored Tag SRAM

Notes

  1. The minimum operating system is 2.5.1 HW: 11/97 or 2.6 HW: 3/98.
  2. Solaris 2.5.1 patch >=103640-27 and 2.6 patch >=105181-14 are required.
  3. OBP 3.2 Version 21 is required. OBP 3.2 Version 29 is recommended.
  4. Use the limit-ecache-size OBP command before installing Solaris 2.5.1 and before booting Solaris 2.5.1 without patch 103640-27.
  5. Use the limit-ecache-size OBP command before installing Solaris 2.6 and before booting Solaris 2.6 without patch 105181-14.
  6. Mixing module speeds within a system is not supported.
  7. The 8-slot Gigaplane operating at 100MHz with seven CPU/Memory boards and 400MHz modules does not support N+1 Power.

Compatibility Notes

  1. Clock 501-2975 is not supported.
  2. The E6000 and E6500 require Clock 501-5365 for a 5:1 clock ratio.
  3. The E3x00, E4x00, and E5x00 require Clock 501-5365 for a 5:1 clock ratio if 84MHz system boards are installed.
  4. Clock 501-4286 or 501-4946 is supported in the E3x00, E4x00, and E5x00 if the centerplane and all system boards are 100MHz.
  5. Clock 501-5365 is supported if 84MHz or 100MHz system boards are installed in the E3x00, E4x00, and E5x00.

Reference

CPU Module Installation Guide, 806-0960.

400MHz UltraSPARC II Module

E10000

Option 2580

501-5815
8MB Cache Blaze
Sony Espejo Mirrored Data SRAM
Sony Mirrored Tag SRAM

Notes

  1. The minimum SSP release is 3.3.
  2. Patch >=108885-09 (SSP 3.3) or >=110304-05 (SSP 3.4) is required.
    (No patching is required for SSP 3.5.)
  3. Mixing module speeds within a system is supported.
  4. A minimum of one processor per System Board is required.
  5. Set the clock multiplier to 2:1 with the command:
    sys_clock -p two-to-one -s -i 100000000
  6. System Boards 501-4347, 501-4786, and 501-4903 are not compatible with the 400MHz UltraSPARC module.
  7. System Boards 501-5240, 501-5278, 501-5279, and 501-5693 are compatible with the 400MHz UltraSPARC module.

Reference:

System Board Installation and Configuration Guide, 805-7189.

WebToneWebToneWebToneWebTone
 Copyright 1994-2003 Sun Microsystems, Inc.,  901 San Antonio Road, Palo Alto, CA 94303 USA.  All rights reserved.
 Legal Terms Privacy Policy Feedback