400MHz UltraSPARC II Module
E3000 / E4000 / E5000 / E3500 / E4500 / E5500
Option 2570
501-4995 |
4MB Cache Sapphire-Black |
Notes
- The minimum operating system is 2.5.1 HW: 11/97 or 2.6 HW: 3/98.
- Solaris 2.5.1 patches
>=103640-06
are required.
- OBP 3.2 Version 18 is required.
- Mixing module cache sizes on a single board requires OBP >=3.2.21.
- Mixing module speeds within a system is not supported.
- The 8-slot Gigaplane operating at 100MHz with seven CPU/Memory
boards and 400MHz modules does not support N+1 Power.
Compatibility Notes
- Clock 501-2975 is not supported.
- This module requires 100MHz CPU/Memory and I/O boards.
- The E3x00 supports Clocks 501-4286, 501-4946, and 501-5365.
- The E4x00 and E5x00 do not support Clock 501-4286.
- The E4x00 and E5x00 support Clocks 501-4946 and 501-5365.
- The E4000 and E5000 require a 100MHz Centerplane upgrade.
- This module is not supported in the E6000 or E6500.
Reference
-
CPU Module Installation Guide, 806-0960.
400MHz UltraSPARC II Module
E10000
Option 2570
501-4995 |
4MB Cache Sapphire-Black |
Notes
- The minimum operating system is 2.5.1 HW: 11/97 or 2.6 HW: 3/98.
- Mixing module speeds within a system is supported.
- A minimum of one processor per System Board is required.
- Set the clock multiplier to 2:1 with the command:
- sys_clock -p two-to-one -s -i 100000000
- System Boards 501-4347, 501-4786, and 501-4903 are not compatible
with the 400MHz UltraSPARC module.
- System Boards 501-5240, 501-5278, 501-5279, and 501-5693 are compatible
with the 400MHz UltraSPARC module.
Reference:
-
System Board Installation and Configuration Guide, 805-7189.
400MHz UltraSPARC II Module
E3000 / E4000 / E5000 / E3500 / E4500 / E5500
Option 2570
501-5425 |
4MB Cache Sapphire-Black |
Notes
- The minimum operating system is 2.5.1 HW: 11/97 or 2.6 HW: 3/98.
- Solaris 2.5.1 patches
>=103640-06
are required.
- OBP 3.2 Version 18 is required.
- Mixing module cache sizes on a single board requires OBP >=3.2.21.
- Mixing module speeds within a system is not supported.
- The 8-slot Gigaplane operating at 100MHz with seven CPU/Memory
boards and 400MHz modules does not support N+1 Power.
Compatibility Notes
- Clock 501-2975 is not supported.
- This module requires 100MHz CPU/Memory and I/O boards.
- The E3x00 supports Clocks 501-4286, 501-4946, and 501-5365.
- The E4x00 and E5x00 do not support Clock 501-4286.
- The E4x00 and E5x00 support Clocks 501-4946 and 501-5365.
- The E4000 and E5000 require a 100MHz Centerplane upgrade.
- This module is not supported in the E6000 or E6500.
Reference
-
CPU Module Installation Guide, 806-0960.
400MHz UltraSPARC II Module
E10000
Option 2570
501-5425 |
4MB Cache Sapphire-Black |
Notes
- The minimum operating system is 2.5.1 HW: 11/97 or 2.6 HW: 3/98.
- Mixing module speeds within a system is supported.
- A minimum of one processor per System Board is required.
- Set the clock multiplier to 2:1 with the command:
- sys_clock -p two-to-one -s -i 100000000
- System Boards 501-4347, 501-4786, and 501-4903 are not compatible
with the 400MHz UltraSPARC module.
- System Boards 501-5240, 501-5278, 501-5279, and 501-5693 are compatible
with the 400MHz UltraSPARC module.
Reference:
-
System Board Installation and Configuration Guide, 805-7189.
400MHz UltraSPARC II Module
E3000 / E4000 / E5000 / E3500 / E4500 / E5500
Option 2570
501-5585 |
4MB Cache Sapphire-Black |
Notes
- The minimum operating system is 2.5.1 HW: 11/97 or 2.6 HW: 3/98.
- Solaris 2.5.1 patches
>=103640-06
are required.
- OBP 3.2 Version 18 is required.
- Mixing module cache sizes on a single board requires OBP >=3.2.21.
- Mixing module speeds within a system is not supported.
- The 8-slot Gigaplane operating at 100MHz with seven CPU/Memory
boards and 400MHz modules does not support N+1 Power.
Compatibility Notes
- Clock 501-2975 is not supported.
- This module requires 100MHz CPU/Memory and I/O boards.
- The E3x00 supports Clocks 501-4286, 501-4946, and 501-5365.
- The E4x00 and E5x00 do not support Clock 501-4286.
- The E4x00 and E5x00 support Clocks 501-4946 and 501-5365.
- The E4000 and E5000 require a 100MHz Centerplane upgrade.
- This module is not supported in the E6000 or E6500.
Reference
-
CPU Module Installation Guide, 806-0960.
400MHz UltraSPARC II Module
E10000
Option 2570
501-5585 |
4MB Cache Sapphire-Black |
Notes
- The minimum operating system is 2.5.1 HW: 11/97 or 2.6 HW: 3/98.
- Mixing module speeds within a system is supported.
- A minimum of one processor per System Board is required.
- Set the clock multiplier to 2:1 with the command:
- sys_clock -p two-to-one -s -i 100000000
- System Boards 501-4347, 501-4786, and 501-4903 are not compatible
with the 400MHz UltraSPARC module.
- System Boards 501-5240, 501-5278, 501-5279, and 501-5693 are compatible
with the 400MHz UltraSPARC module.
Reference:
-
System Board Installation and Configuration Guide, 805-7189.
400MHz UltraSPARC II Module
E3000 / E4000 / E5000 / E6000 E3500 / E4500 / E5500 / E6500
Option 2580
501-5235 |
8MB Cache Sapphire-Black |
Notes
- The minimum operating system is 2.5.1 HW: 11/97 or 2.6 HW: 3/98.
- Solaris 2.5.1 patch
>=103640-27
and 2.6 patch
>=105181-14 are required.
- OBP 3.2 Version 21 is required. OBP 3.2 Version 24 is recommended.
- Use the limit-ecache-size OBP command before installing Solaris
2.5.1 and before booting Solaris 2.5.1 without patch
103640-27.
- Use the limit-ecache-size OBP command before installing Solaris 2.6
and before booting Solaris 2.6 without patch
105181-14.
- Mixing module speeds within a system is not supported.
- The 8-slot Gigaplane operating at 100MHz with seven CPU/Memory
boards and 400MHz modules does not support N+1 Power.
Compatibility Notes
- Clock 501-2975 is not supported.
- The E6000 and E6500 require Clock 501-5365 for a 5:1 clock ratio.
- The E3x00, E4x00, and E5x00 require Clock 501-5365 for a 5:1 clock
ratio if 84MHz system boards are installed.
- Clock 501-4286 or 501-4946 is supported in the E3x00, E4x00,
and E5x00 if the centerplane and all system boards are 100MHz.
- Clock 501-5365 is supported if 84MHz or 100MHz system boards are
installed in the E3x00, E4x00, and E5x00.
Reference
-
CPU Module Installation Guide, 806-0960.
400MHz UltraSPARC II Module
E10000
Option 2580
501-5235 |
8MB Cache Sapphire-Black |
Notes
- Mixing module speeds within a system is supported.
- A minimum of one processor per System Board is required.
- Set the clock multiplier to 2:1 with the command:
- sys_clock -p two-to-one -s -i 100000000
- System Boards 501-4347, 501-4786, and 501-4903 are not compatible
with the 400MHz UltraSPARC module.
- System Boards 501-5240, 501-5278, 501-5279, and 501-5693 are compatible
with the 400MHz UltraSPARC module.
Reference:
-
System Board Installation and Configuration Guide, 805-7189.
400MHz UltraSPARC II Module
E3000 / E4000 / E5000 / E6000 E3500 / E4500 / E5500 / E6500
Option 2580
501-5661 |
8MB Cache Sapphire-Black |
Notes
- The minimum operating system is 2.5.1 HW: 11/97 or 2.6 HW: 3/98.
- Solaris 2.5.1 patch
>=103640-27
and 2.6 patch
>=105181-14 are required.
- OBP 3.2 Version 21 is required. OBP 3.2 Version 24 is recommended.
- Use the limit-ecache-size OBP command before installing Solaris
2.5.1 and before booting Solaris 2.5.1 without patch
103640-27.
- Use the limit-ecache-size OBP command before installing Solaris 2.6
and before booting Solaris 2.6 without patch
105181-14.
- Mixing module speeds within a system is not supported.
- The 8-slot Gigaplane operating at 100MHz with seven CPU/Memory
boards and 400MHz modules does not support N+1 Power.
Compatibility Notes
- Clock 501-2975 is not supported.
- The E6000 and E6500 require Clock 501-5365 for a 5:1 clock ratio.
- The E3x00, E4x00, and E5x00 require Clock 501-5365 for a 5:1 clock
ratio if 84MHz system boards are installed.
- Clock 501-4286 or 501-4946 is supported in the E3x00, E4x00,
and E5x00 if the centerplane and all system boards are 100MHz.
- Clock 501-5365 is supported if 84MHz or 100MHz system boards are
installed in the E3x00, E4x00, and E5x00.
Reference
-
CPU Module Installation Guide, 806-0960.
400MHz UltraSPARC II Module
E10000
Option 2580
501-5661 |
8MB Cache Sapphire-Black |
Notes
- Mixing module speeds within a system is supported.
- A minimum of one processor per System Board is required.
- Set the clock multiplier to 2:1 with the command:
- sys_clock -p two-to-one -s -i 100000000
- System Boards 501-4347, 501-4786, and 501-4903 are not compatible
with the 400MHz UltraSPARC module.
- System Boards 501-5240, 501-5278, 501-5279, and 501-5693 are compatible
with the 400MHz UltraSPARC module.
Reference:
-
System Board Installation and Configuration Guide, 805-7189.
400MHz UltraSPARC II Module
E3000 / E4000 / E5000 / E6000 E3500 / E4500 / E5500 / E6500
Option 2580
501-5762 |
8MB Cache Sapphire-Black |
Notes
- The minimum operating system is 2.5.1 HW: 11/97 or 2.6 HW: 3/98.
- Solaris 2.5.1 patch
>=103640-27
and 2.6 patch
>=105181-14 are required.
- OBP 3.2 Version 21 is required. OBP 3.2 Version 24 is recommended.
- Use the limit-ecache-size OBP command before installing Solaris
2.5.1 and before booting Solaris 2.5.1 without patch
103640-27.
- Use the limit-ecache-size OBP command before installing Solaris 2.6
and before booting Solaris 2.6 without patch
105181-14.
- Mixing module speeds within a system is not supported.
- The 8-slot Gigaplane operating at 100MHz with seven CPU/Memory
boards and 400MHz modules does not support N+1 Power.
- For more information on 501-5762, see ECO WO_16898.
Compatibility Notes
- Clock 501-2975 is not supported.
- The E6000 and E6500 require Clock 501-5365 for a 5:1 clock ratio.
- The E3x00, E4x00, and E5x00 require Clock 501-5365 for a 5:1 clock
ratio if 84MHz system boards are installed.
- Clock 501-4286 or 501-4946 is supported in the E3x00, E4x00,
and E5x00 if the centerplane and all system boards are 100MHz.
- Clock 501-5365 is supported if 84MHz or 100MHz system boards are
installed in the E3x00, E4x00, and E5x00.
Reference
-
CPU Module Installation Guide, 806-0960.
400MHz UltraSPARC II Module
E10000
Option 2580
501-5762 |
8MB Cache Sapphire-Black |
Notes
- Mixing module speeds within a system is supported.
- A minimum of one processor per System Board is required.
- Set the clock multiplier to 2:1 with the command:
- sys_clock -p two-to-one -s -i 100000000
- System Boards 501-4347, 501-4786, and 501-4903 are not compatible
with the 400MHz UltraSPARC module.
- System Boards 501-5240, 501-5278, 501-5279, and 501-5693 are compatible
with the 400MHz UltraSPARC module.
- For more information on 501-5762, see ECO WO_16898.
Reference:
-
System Board Installation and Configuration Guide, 805-7189.
400MHz UltraSPARC II Module
E3000 / E4000 / E5000 / E6000 E3500 / E4500 / E5500 / E6500
Option 2580
501-5838 |
8MB Cache Sapphire-Black
IBM Sombra
Mirrored Data SRAM |
Notes
- The minimum operating system is 2.5.1 HW: 11/97 or 2.6 HW: 3/98.
- Solaris 2.5.1 patch
>=103640-27
and 2.6 patch
>=105181-14 are required.
- OBP 3.2 Version 21 is required. OBP 3.2 Version 24 is recommended.
- Use the limit-ecache-size OBP command before installing Solaris
2.5.1 and before booting Solaris 2.5.1 without patch
103640-27.
- Use the limit-ecache-size OBP command before installing Solaris 2.6
and before booting Solaris 2.6 without patch
105181-14.
- Mixing module speeds within a system is not supported.
- The 8-slot Gigaplane operating at 100MHz with seven CPU/Memory
boards and 400MHz modules does not support N+1 Power.
Compatibility Notes
- Clock 501-2975 is not supported.
- The E6000 and E6500 require Clock 501-5365 for a 5:1 clock ratio.
- The E3x00, E4x00, and E5x00 require Clock 501-5365 for a 5:1 clock
ratio if 84MHz system boards are installed.
- Clock 501-4286 or 501-4946 is supported in the E3x00, E4x00,
and E5x00 if the centerplane and all system boards are 100MHz.
- Clock 501-5365 is supported if 84MHz or 100MHz system boards are
installed in the E3x00, E4x00, and E5x00.
Reference
-
CPU Module Installation Guide, 806-0960.
400MHz UltraSPARC II Module
E10000
Option 2580
501-5838 |
8MB Cache Sapphire-Black
IBM Sombra
Mirrored Data SRAM |
Notes
- The minimum SSP release is 3.3.
- Patch
>=108885-09
(SSP 3.3)
or
>=110304-05
(SSP 3.4)
is required.
(No patching is required for SSP 3.5.)
- Mixing module speeds within a system is supported.
- A minimum of one processor per System Board is required.
- Set the clock multiplier to 2:1 with the command:
- sys_clock -p two-to-one -s -i 100000000
- System Boards 501-4347, 501-4786, and 501-4903 are not compatible
with the 400MHz UltraSPARC module.
- System Boards 501-5240, 501-5278, 501-5279, and 501-5693 are compatible
with the 400MHz UltraSPARC module.
Reference:
-
System Board Installation and Configuration Guide, 805-7189.
400MHz UltraSPARC II Module
E3000 / E4000 / E5000 / E6000 E3500 / E4500 / E5500 / E6500
501-6008 |
8MB Cache Sapphire-Black
IBM Sombra
Mirrored Data SRAM |
Notes
- The minimum operating system is 2.5.1 HW: 11/97 or 2.6 HW: 3/98.
- Solaris 2.5.1 patch
>=103640-27
and 2.6 patch
>=105181-14 are require
d.
- OBP 3.2 Version 21 is required. OBP 3.2 Version 29 is recommended.
- Use the limit-ecache-size OBP command before installing Solaris
2.5.1 and before booting Solaris 2.5.1 without patch
103640-27.
- Use the limit-ecache-size OBP command before installing Solaris 2.6
and before booting Solaris 2.6 without patch
105181-14.
- Mixing module speeds within a system is not supported.
- The 8-slot Gigaplane operating at 100MHz with seven CPU/Memory
boards and 400MHz modules does not support N+1 Power.
Compatibility Notes
- Clock 501-2975 is not supported.
- The E6000 and E6500 require Clock 501-5365 for a 5:1 clock ratio.
- The E3x00, E4x00, and E5x00 require Clock 501-5365 for a 5:1 clock
ratio if 84MHz system boards are installed.
- Clock 501-4286 or 501-4946 is supported in the E3x00, E4x00,
and E5x00 if the centerplane and all system boards are 100MHz.
- Clock 501-5365 is supported if 84MHz or 100MHz system boards are
installed in the E3x00, E4x00, and E5x00.
Reference
-
CPU Module Installation Guide, 806-0960.
400MHz UltraSPARC II Module
E10000
501-6008 |
8MB Cache Sapphire-Black
IBM Sombra
Mirrored Data SRAM |
Notes
- The minimum SSP release is 3.3.
- Patch
>=108885-09
(SSP 3.3)
or
>=110304-05
(SSP 3.4)
is required.
(No patching is required for SSP 3.5.)
- Mixing module speeds within a system is supported.
- A minimum of one processor per System Board is required.
- Set the clock multiplier to 2:1 with the command:
- sys_clock -p two-to-one -s -i 100000000
- System Boards 501-4347, 501-4786, and 501-4903 are not compatible
with the 400MHz UltraSPARC module.
- System Boards 501-5240, 501-5278, 501-5279, and 501-5693 are compatible
with the 400MHz UltraSPARC module.
Reference:
-
System Board Installation and Configuration Guide, 805-7189.
400MHz UltraSPARC II Module
E3000 / E4000 / E5000 / E6000 E3500 / E4500 / E5500 / E6500
Option 2580
501-6009 |
8MB Cache Sapphire-Black
IBM Sombra
Mirrored Data SRAM
IBM
Mirrored Tag SRAM |
Notes
- The minimum operating system is 2.5.1 HW: 11/97 or 2.6 HW: 3/98.
- Solaris 2.5.1 patch
>=103640-27
and 2.6 patch
>=105181-14 are require
d.
- OBP 3.2 Version 21 is required. OBP 3.2 Version 29 is recommended.
- Use the limit-ecache-size OBP command before installing Solaris
2.5.1 and before booting Solaris 2.5.1 without patch
103640-27.
- Use the limit-ecache-size OBP command before installing Solaris 2.6
and before booting Solaris 2.6 without patch
105181-14.
- Mixing module speeds within a system is not supported.
- The 8-slot Gigaplane operating at 100MHz with seven CPU/Memory
boards and 400MHz modules does not support N+1 Power.
Compatibility Notes
- Clock 501-2975 is not supported.
- The E6000 and E6500 require Clock 501-5365 for a 5:1 clock ratio.
- The E3x00, E4x00, and E5x00 require Clock 501-5365 for a 5:1 clock
ratio if 84MHz system boards are installed.
- Clock 501-4286 or 501-4946 is supported in the E3x00, E4x00,
and E5x00 if the centerplane and all system boards are 100MHz.
- Clock 501-5365 is supported if 84MHz or 100MHz system boards are
installed in the E3x00, E4x00, and E5x00.
Reference
-
CPU Module Installation Guide, 806-0960.
400MHz UltraSPARC II Module
E10000
Option 2580
501-6009 |
8MB Cache Sapphire-Black
IBM Sombra
Mirrored Data SRAM
IBM
Mirrored Tag SRAM |
Notes
- The minimum SSP release is 3.3.
- Patch
>=108885-09
(SSP 3.3)
or
>=110304-05
(SSP 3.4)
is required.
(No patching is required for SSP 3.5.)
- Mixing module speeds within a system is supported.
- A minimum of one processor per System Board is required.
- Set the clock multiplier to 2:1 with the command:
- sys_clock -p two-to-one -s -i 100000000
- System Boards 501-4347, 501-4786, and 501-4903 are not compatible
with the 400MHz UltraSPARC module.
- System Boards 501-5240, 501-5278, 501-5279, and 501-5693 are compatible
with the 400MHz UltraSPARC module.
Reference:
-
System Board Installation and Configuration Guide, 805-7189.
400MHz UltraSPARC II Module
E3000 / E4000 / E5000 / E6000 E3500 / E4500 / E5500 / E6500
Option 2580
501-5814 |
8MB Cache Blaze
IBM Sombra
Mirrored Data SRAM
IBM
Mirrored Tag SRAM |
Notes
- The minimum operating system is 2.5.1 HW: 11/97 or 2.6 HW: 3/98.
- Solaris 2.5.1 patch
>=103640-27
and 2.6 patch
>=105181-14 are required.
- OBP 3.2 Version 21 is required. OBP 3.2 Version 29 is recommended.
- Use the limit-ecache-size OBP command before installing Solaris
2.5.1 and before booting Solaris 2.5.1 without patch
103640-27.
- Use the limit-ecache-size OBP command before installing Solaris 2.6
and before booting Solaris 2.6 without patch
105181-14.
- Mixing module speeds within a system is not supported.
- The 8-slot Gigaplane operating at 100MHz with seven CPU/Memory
boards and 400MHz modules does not support N+1 Power.
Compatibility Notes
- Clock 501-2975 is not supported.
- The E6000 and E6500 require Clock 501-5365 for a 5:1 clock ratio.
- The E3x00, E4x00, and E5x00 require Clock 501-5365 for a 5:1 clock
ratio if 84MHz system boards are installed.
- Clock 501-4286 or 501-4946 is supported in the E3x00, E4x00,
and E5x00 if the centerplane and all system boards are 100MHz.
- Clock 501-5365 is supported if 84MHz or 100MHz system boards are
installed in the E3x00, E4x00, and E5x00.
Reference
-
CPU Module Installation Guide, 806-0960.
400MHz UltraSPARC II Module
E10000
Option 2580
501-5814 |
8MB Cache Blaze
IBM Sombra
Mirrored Data SRAM
IBM
Mirrored Tag SRAM |
Notes
- The minimum SSP release is 3.3.
- Patch
>=108885-09
(SSP 3.3)
or
>=110304-05
(SSP 3.4)
is required.
(No patching is required for SSP 3.5.)
- Mixing module speeds within a system is supported.
- A minimum of one processor per System Board is required.
- Set the clock multiplier to 2:1 with the command:
- sys_clock -p two-to-one -s -i 100000000
- System Boards 501-4347, 501-4786, and 501-4903 are not compatible
with the 400MHz UltraSPARC module.
- System Boards 501-5240, 501-5278, 501-5279, and 501-5693 are compatible
with the 400MHz UltraSPARC module.
Reference:
-
System Board Installation and Configuration Guide, 805-7189.
400MHz UltraSPARC II Module
E3000 / E4000 / E5000 / E6000 E3500 / E4500 / E5500 / E6500
Option 2580
501-5815 |
8MB Cache Blaze
Sony Espejo
Mirrored Data SRAM
Sony
Mirrored Tag SRAM |
Notes
- The minimum operating system is 2.5.1 HW: 11/97 or 2.6 HW: 3/98.
- Solaris 2.5.1 patch
>=103640-27
and 2.6 patch
>=105181-14 are required.
- OBP 3.2 Version 21 is required. OBP 3.2 Version 29 is recommended.
- Use the limit-ecache-size OBP command before installing Solaris
2.5.1 and before booting Solaris 2.5.1 without patch
103640-27.
- Use the limit-ecache-size OBP command before installing Solaris 2.6
and before booting Solaris 2.6 without patch
105181-14.
- Mixing module speeds within a system is not supported.
- The 8-slot Gigaplane operating at 100MHz with seven CPU/Memory
boards and 400MHz modules does not support N+1 Power.
Compatibility Notes
- Clock 501-2975 is not supported.
- The E6000 and E6500 require Clock 501-5365 for a 5:1 clock ratio.
- The E3x00, E4x00, and E5x00 require Clock 501-5365 for a 5:1 clock
ratio if 84MHz system boards are installed.
- Clock 501-4286 or 501-4946 is supported in the E3x00, E4x00,
and E5x00 if the centerplane and all system boards are 100MHz.
- Clock 501-5365 is supported if 84MHz or 100MHz system boards are
installed in the E3x00, E4x00, and E5x00.
Reference
-
CPU Module Installation Guide, 806-0960.
400MHz UltraSPARC II Module
E10000
Option 2580
501-5815 |
8MB Cache Blaze
Sony Espejo
Mirrored Data SRAM
Sony
Mirrored Tag SRAM |
Notes
- The minimum SSP release is 3.3.
- Patch
>=108885-09
(SSP 3.3)
or
>=110304-05
(SSP 3.4)
is required.
(No patching is required for SSP 3.5.)
- Mixing module speeds within a system is supported.
- A minimum of one processor per System Board is required.
- Set the clock multiplier to 2:1 with the command:
- sys_clock -p two-to-one -s -i 100000000
- System Boards 501-4347, 501-4786, and 501-4903 are not compatible
with the 400MHz UltraSPARC module.
- System Boards 501-5240, 501-5278, 501-5279, and 501-5693 are compatible
with the 400MHz UltraSPARC module.
Reference:
-
System Board Installation and Configuration Guide, 805-7189.
|