SBus I/O Board

E10000

Option 2730

501-4349 501-4478

Notes

  1. Install only one TRI/S. Do NOT install any board in the second slot.
  2. Install SCI and UDWIS/S on separate SBus channels.

SBus I/O Board 501-4349 Notes

  1. Install FC100/S in Slot 0 and DWIS/S in Slot 1.
  2. Install GBE/S 1.x in Slot 0. There are no slot restrictions for GBE/S 2.0.
  3. Install SunFastEthernet 2.x in Slot 0 and DWIS/S in Slot 1.
  4. Install SunSwift in Slot 0 and DWIS/S in Slot 1.
  5. SSP software controls whether the system will boot when SBus boards are installed in Slot 1 of SBus I/O board 501-4349. Problems may occur if SBus slot restrictions are not followed.
501-4349
Slot 1
SSP 3.0
<=104853-04
SSP 3.0
>=104853-05
SSP 3.1
<=105684-06
SSP 3.1
>=105684-07
SSP 3.1.1 SSP 3.2
SunSwift
FastEthernet
GBE/S 1.x
FC100/S
will not boot
will not boot
will not boot
will boot
will boot
will boot
will boot
will boot
will not boot
will not boot
will not boot
will boot
will boot
will boot
will boot
will boot
will boot
will boot
will boot
will boot
will boot
will boot
will boot
will boot

SBus I/O Board 501-4478 Notes

  1. SSP software controls whether the system will boot when SBus boards are installed in Slot 1 of SBus I/O board 501-4478.
  2. There are no slot restrictions for FC100/S, GBE/S, SunFastEthernet, or SunSwift when SBus I/O board 501-4478 is used with new versions of SSP software.*
501-4349
Slot 1
SSP 3.0
<=104853-04
SSP 3.0*
>=104853-05
SSP 3.1
<=105684-06
SSP 3.1*
>=105684-07
SSP 3.1.1* SSP 3.2*
SunSwift
FastEthernet
GBE/S 1.x
FC100/S
will not boot
will not boot
will not boot
will boot
will boot
will boot
will boot
will boot
will not boot
will not boot
will not boot
will boot
will boot
will boot
will boot
will boot
will boot
will boot
will boot
will boot
will boot
will boot
will boot
will boot

References

  1. Ultra Enterprise 10000 System Service Manual, 805-2917.