Differential Fast/Wide SCSI (DWIS/S)
SS5 / SS10 / SS20 / SS600 / SS1000 / SC2000
A11 / A12 / A14
E3000 / E4000 / E5000 / E6000
E3500 / E4500 / E5500 / E6500 / E10000
Option 1062
370-1704 |
QLogic SP1710401 |
Notes
- The minimum operating system is Solaris 2.3.
- The DWIS/S supports up to 15 targets on the SCSI bus.
- Do NOT mix narrow (8-bit) and wide (16-bit) SCSI devices on the same
controller under Solaris 2.3. Install Patch
101378-01.
- Warning messages are displayed if fast/wide SCSI is enabled under Solaris
2.3. Install Patch
101378-01.
- Set scsi_options=0x3f8 in /etc/system to enable
fast/wide transfers.
- The 2.1GB Disk Drive requires 0420 Firmware (370-1412-03) for optimal
performance. Set scsi_options=0xf8 in the /etc/system
file if older disk drive firmware is used.
- Install SunSwift in Slot 0 and DWIS/S in Slot 1 when installing SunSwift
and DWIS/S on an E10000 I/O board. Refer to BugIDs 4046986, 4049704, and
4091053.
Reference
-
SBus Intelligent SCSI Host Adapter, 801-5355.
|