Differential Fast/Wide SCSI (DWIS/S)

Codename: Sport16

SS5 / SS10 / SS20 / SS600 / SS1000 / SC2000
A11 / A12 / A14
E3000 / E4000 / E5000 / E6000
E3500 / E4500 / E5500 / E6500 / E10000

Option 1062

370-1704
QLogic SP1710401

Notes

  1. The minimum operating system is Solaris 2.3.
  2. The DWIS/S supports up to 15 targets on the SCSI bus.
  3. Do NOT mix narrow (8-bit) and wide (16-bit) SCSI devices on the same controller under Solaris 2.3. Install Patch 101378-01.
  4. Warning messages are displayed if fast/wide SCSI is enabled under Solaris 2.3. Install Patch 101378-01.
  5. Set scsi_options=0x3f8 in /etc/system to enable fast/wide transfers.
  6. The 2.1GB Disk Drive requires 0420 Firmware (370-1412-03) for optimal performance. Set scsi_options=0xf8 in the /etc/system file if older disk drive firmware is used.
  7. Install SunSwift in Slot 0 and DWIS/S in Slot 1 when installing SunSwift and DWIS/S on an E10000 I/O board. Refer to BugIDs 4046986, 4049704, and 4091053.