Sun Microsystems, Inc.
spacer spacer
spacer   Sun System Handbook Home | Systems | Components | General Info | Search | Feedback 
spacer
black dot
 
black fade
 

SCSI RAID Controller (SRC/P)

A25 / A26 / A33 / A34 / A35 / Netra 20

Options 6542 / 6602

375-0078
DPT SmartRAID Millennium PM3755U2B
w Battery Backup Module BB4050
w SCSI Expansion Module SX4055U2-2
w 64MB ECC EDO DIMM DM4050-64
3.3/5V 64Bit 33MHz
SRC/P 375-0078
SmartRAID Millennium
DPT PM3755U2B
No Sun part number
 
Battery Backup Module
DPT BB4550
375-0082

64MB DIMM
DPT DM4050-64
No Sun part number

SCSI Expansion Module
DPT SX4055U2-2
No Sun part number

Notes

  1. The minimum operating system is Solaris 2.6 Hardware: 3/98.
  2. The E250 and E450 require OBP >=3.12.
  3. The SRC/P requires a 64-Bit PCI slot.
  4. Internal Option 6602 is only available for the E450 (A25).
  5. The maximum high-speed disk cache memory is 256MB.

Cable Notes

  1. The A25 requires internal 8-Disk Backplane Cable 530-2744.
  2. The 68-pin VHDCI connector on Cables 530-2452-01 and 530-2453-01 is centered in the housing.
  3. The 68-pin VHDCI connector on Cables 530-2452-02 and 530-2453-02 is offset in the housing.
  4. Cables with centered VHDCI connectors are not usable at the same time on the A and B ports, due to the thickness of the connector shell. The shell thickness was reduced on cables 530-2452-02 and 530-2453-02.
  5. Cable 530-2453-02 was released in May 1999.
  6. Cable 530-2452-02 was released in May 2001.

References

  1. SRC/P Installation Guide, 805-7752.
  2. SRC/P User's Guide, 805-6768.
  3. E450 Internal RAID Storage Option Installation Guide, 805-6765.

WebToneWebToneWebToneWebTone
 Copyright 1994-2003 Sun Microsystems, Inc.,  901 San Antonio Road, Palo Alto, CA 94303 USA.  All rights reserved.
 Legal Terms Privacy Policy Feedback