Disks (System Capacity)
|
Number of disk drives (with spares) |
9910: 5 to 48
9960: 5 to 512
|
Hot spares (maximum) |
9910: 4
9960: 16 |
Individual disk capacities, 3-in form factor, 10K RPM |
18 GB, 72 GB, 181 GB |
Total raw capacity per system |
9910: 8.7 TB
9960: 94.9 TB |
Data Cache
|
Maximum |
9910: 16 GB
9960: 32 GB |
Minimum |
9910: 1 GB
9960: 2 GB |
Control Memory
|
Up to 1.5 GB |
Logical Device Support
|
Up to 4096 |
Client-Host Interface
Processors (CHIP)
|
Number of CHIP pairs |
9910: Up to 3
9960: Up to 4 |
Simultaneous data transfers per CHIP pair |
4 or 8 |
Physical interfaces per CHIP pair |
4 or 8 |
Physical Interfaces
per System
|
Physical Interfaces per System |
9910: 24
9960: 32 |
Fibre Channel (fiber-optic cable) |
9910: 0, 4, 8, 12, 16, 20, or 24
9960: 0, 4, 8, 12, 16, 20, 24, 28, or 32 |
Extended Serial Adapters |
9910: 0, 4, 8, 12, 16, 20, or 24
9960: 0, 4, 8, 12, 16, 20, 24, 28, or 32 |
Array Control Processor
|
Number of ACP pairs per system |
9910: 1
9960: Up to 4 |
Physical array paths per ACP pair |
8 |
Maximum disks per array path |
9910: 12
9960: 32 |
Simultaneous transfers per ACP pair |
To cache
|
9910: 4
9960: 8 |
To disk array
|
8 |
Transfer rates |
|
Per disk array path
|
Up to 100 MB/sec |
Per ACP pair (to cache)
|
Up to 800 MB/sec |
Per fully configured system
|
9910: 3.2 GB/sec
9960: 6.4 GB/sec |
Environment
|
Power |
9910: 3.3 kVA
9960 (Control Frame): 1.6 kVA
9960 (Array Frame): 3.7 kVA (1-4); 2.9 kVA (5-6) |
Heat |
9910: 3.1 kW
9960 (Control Frame): 1.5 kW
9960 (Array Frame): 3.4 kW (1-4); 2.6 kW (5-6) |
Temperature & Humidity |
Operating1: 60 (16) to 90 (32), 20% to 80% relative
humidity.
Non-Operating: 14 (-10) to 109 (43), 8% - 90 % relative humidity.
|
1 Environmental
specification for operating condition should be satisfied before the disk
subsystem is powered on. The maximum temperature of 90°F (32°C) should be
strictly satisfied at the air inlet portion of the subsystem. The recommended
temperature range is 70-75°F (21-24°C). |
Dimensions and Weights |
Height |
1,790 mm (70.5 in.) |
Width (with two side panels) |
9910: 700 mm (27.6 in.)
9960 (Control Frame): 750 mm (29.5 in.)
9960 (Array Frame): 600 mm (23.6 in.)
|
Depth |
800 mm (31.5 in.) |
Weight |
9910: 524 kg (1,153 lb.)
9960 (Control Frame): 451 kg (992 lb.)
9960 (Array Frame): 469 kg (1,031 lb.)
|
Power Connectors |
System |
Geography |
Power |
Quantity |
Plug |
Connector |
9910 |
US |
Single-Phase |
2
|
Russellstoll 3720DP
N/A - Controller |
Russellstoll 3913 or Russellstoll 3743
N/A - Controller |
Europe |
Single-Phase |
2
|
N/A (Hardwire)
N/A - Controller |
N/A (Hardwire)
N/A - Controller |
9960 (Control Frame) |
US |
Single-Phase |
2
|
Russellstoll 3720DP |
Russellstoll 3913 or Russellstoll 3743 |
3-Phase |
0
|
N/A – Powered from first Array Frame |
N/A – Powered from first Array Frame |
Europe |
Single-Phase |
2
|
N/A (Hardwire) |
N/A (Hardwire) |
3-Phase |
0
|
N/A – Powered from first Array Frame |
N/A – Powered from first Array Frame |
9960 (Array Frame) |
US |
Single-Phase |
2
|
Russellstoll 3720DP |
Russellstoll 3913 or Russellstoll 3743 |
3-Phase |
2
|
Russellstoll 3760 or Russellstoll 3760PDG |
Russellstoll 3754 or Russellstoll 3934 |
Europe |
Single-Phase |
2
|
N/A (Hardwire) |
N/A (Hardwire) |
3-Phase |
2
|
N/A (Hardwire) |
N/A (Hardwire) |