Sun Microsystems, Inc.
spacer spacer
spacer   Sun System Handbook Home | Systems | Components | General Info | Search | Feedback 
spacer
black dot
 
black fade
 

Sun StorEdge[tm] L9 Tape Autoloader: Hardware Specifications

Tape Drives
DLT[tm]1 DLT1 LVD Single Ended 40GB 1/2-Inch Tape Drive
DLT 8000 DLT 8000 HV Differential SCSI 40-80GB 1/2-Inch Tape Drive (HP C7202-80008)
LTO LTO High Voltage Differential SCSI Tape Drive
Note: Recommended maximum of two Sun StorEdge L9 autoloaders per host adapter.
Environment & Power
Temperature & Humidity Operating - 10 ºC to 35 ºC (50 ºF to 95 ºF), 20% to 80% relative humidity, noncondensing.
Nonoperating - -35 ºC to 65 ºC (-31 ºF to 149 ºF), 10% to 90% relative humidity, noncondensing.
Maximum Heat Dissipation 425 BTU/hr; 105kCal/hr; 125 W
AC Voltage (minimum) 100 - 240 VAC (autoselecting)
Frequency 50 - 60 Hz
Power Inlet Standard AC cord with hot-neutral-ground
Power Consumption
  • Typical - 100 W
  • Maximum - 125 W
  • Stand-by - 14 W
  • Average running - 100 - 127 V, 1.8 A; 220 - 240 V, 0.9 A
Dimensions and Weights
Item Desktop Rackmount
Height 23.5 cm (9.25 in) 21.9 cm (8.63 in)
Width 22.9 cm (9.0 in) 21.9 cm (8.63 in)
Depth 66 cm (26.0 in) 66 cm (26.0 in)
Weight 24.7 kg (54.3 lb) 22.0 kg (57.5 lb)
Regulations
Meets or exceeds the following requirements:
Safety UL 1950 Listed, CSA C22.2-No. 950, TUV-EN60950
Emission FCC Part 15B Class B, CE Mark, VCCI Class 2, C-Tick, VDE 0871/6.78
Capacity and Performance
DLT1
DLT8000
LTO
Number of Tape Drives One One One
Number of Cartridges Nine Nine Nine
Cartridge Capacity (native) 40 GB
40 GB 100 GB
Autoloader Capacity (native) 360 GB
360 GB 900 GB
Average Tape Exchange 35 seconds 35 seconds 35 seconds
Average Access Time 68 seconds 60 seconds 71 seconds
Tape Load Time from BOT 59 seconds 37 seconds 25 seconds
Unload Time from BOT 17 seconds 17 seconds 13 seconds
Tape Rewind Time 135 seconds 20 seconds 4.1 m/sec.
Operating Interface LVD/SE SCSI HVD SCSI LVDS/HVDS SCSI
Host Software Solaris[tm] Operating Environment 2.6, 7, 8
VERITAS NetBackup software version 3.4 or later
Solstice Backup[tm] software version 5.5.1 or later
Solaris[tm] Operating Environment 2.6, 7, 8
VERITAS NetBackup software version 3.2 or later
Solstice Backup[tm] software version 5.5.1 or later
Solaris[tm] Operating Environment 2.6, 7, 8
VERITAS NetBackup software version 3.2 or later
Solstice Backup[tm] software version 5.5.1 or later

 


WebToneWebToneWebToneWebTone
 Copyright 1994-2003 Sun Microsystems, Inc.,  901 San Antonio Road, Palo Alto, CA 94303 USA.  All rights reserved.
 Legal Terms Privacy Policy Feedback