Feature
|
N8400
- Enterprise 420R and T3 arrays mounted in a rack |
N8600
- Enterprise 4500 with T3 arrays mounted in racks |
Supported naming environments |
NIS, NIS+, DNS, LDAP |
NIS, NIS+, DNS, LDAP |
Network protocol support |
NFS versions 2 and 3 over UDP or TCP, CIFS |
NFS versions 2 and 3 over UDP or TCP, CIFS |
ECC memory |
4096MB |
8192MB |
Nonvolatile memory |
256MB per array |
256MB per array |
NIC expansion capacity
|
3.3v, 33/66 MHz, 32/64
bit PC slot
5v, 33 MHz, 32/64 bit PC slot |
3 SBUS slots |
Optional NIC connectivity |
Single 10/100-BaseT Ethernet, Gigabit Ethernet, Quad Fast
Ethernet |
Single 10/100-BaseT Ethernet,
Gigabit Ethernet, Quad Fast Ethernet |
Disk Drives
|
73GB FC-AL |
73GB FC-AL |
RAID storage capacity |
Minimum: 18 X 73-GB FC-AL drives
Maximum: 72 X 73-GB FC-AL drives
|
Minimum: 18 X 73-GB FC-AL drives
Maximum: 72 X 73-GB FC-AL drives |
Maximum usable capacity |
4TB |
10TB |
Minimum file systems/volumes
Maximum file systems/volumes |
One per array
No limit |
One per array
No limit |
RAID level |
Hardware RAID 5 |
Hardware RAID 5 |
Maximum RAID group size |
7 data/1 pa ity/1 hot spare |
7 data/1 pa ity/1 hot spare |
|
Full-duplex 10/100-BaseT Ethernet |
Standard |
Standard |
Diagnostic LEDs |
Standard |
Standard |
Redundant hot-plug system cooling fans |
Standard |
Standard |
Redundant hot-plug power supplies (N+1) |
Standard |
Standard |
Hot-spare |
Standard |
Standard |
Dual power cords |
Standard |
Standard |
Rack-mount kit |
Optional |
Optional |
Environment
|
N8400
Filer Controller (E420R) |
N8600
Filer Controller (E4500) |
N8400/N8600
Filer Array (T3) |
AC input |
100 - 240 VAC, 47 - 63 Hz, 0.4 K VA, 6.25
A |
100 - 240 VAC, 47 - 63 Hz, 12 A |
100 - 240 VAC, 47-63 Hz, 5 A |
Temperature |
Operating: 5° C to 40° C
(41° F to 104° F)
Nonoperating: -40° C to 60° C (-40° F to 140° F) |
Operating: 5° C to 40° C
(41° F to 104° F)
Nonoperating: -40° C to 60° C (-40° F to 140° F) |
Operating: 5° C to 35° C
(41° F to 95° F)
Nonoperating: -20° C to 60° C (-4° F to 140° F) |
Humidity |
Operating: 20% to 80% relative humidity,
noncondensing
Nonoperating: 5% to 95% relative humidity, noncondensing |
Operating: 20% to 80% relative humidity,
noncondensing
Nonoperating: 5% to 93% relative humidity, noncondensing |
Operating: 20% to 80% relative humidity,
noncondensing
Nonoperating: 5% to 93% relative humidity, noncondensing |
Altitude |
Operating: 3000 m (10, 000 ft.)
Nonoperating: 12,000 m (40, 000 ft.) |
Operating: 3000 m (10, 000 ft.)
Nonoperating: 12,000 m (40, 000 ft.) |
Operating: -300 m to 3000 m (-1000
ft. to 10, 000 ft.)
Nonoperating: -300 m to 12,000 m (-1000 ft. to 40, 000 ft.) |
Vibration |
Operating: 0.2 G peak, 5-500 Hz (swept
sine); 0.0002 G2/Hz, 5-500 Hz (random)
Nonoperating: N/A |
Operating: N/A
Nonoperating: N/A |
Operating: 0.2 G peak, 5-500 Hz (swept
sine); 0.0002 G2/Hz, 5-500 Hz (random); 0.25 G,
5-500 Hz (any axis)
Nonoperating: 1.0 G, 5-500 Hz (any axis) |
Shock |
Operating: 4 G peak, 11 mS half-sine
pulse
Nonoperating: N/A |
Operating: N/A
Nonoperating: N/A |
Operating: 4 G peak, 11 mS half-sine
pulse
Nonoperating: 10 G peak, 11 mS half-sine pulse |
Regulations
Meets or exceeds the following requirements:
|
N8400 Filer Controller (E420R) |
N8600 Filer Controller
(E4500) |
N8400/N8600 Filer Array
(T3) |
Safety |
UL 1950, CSA C 22.2 No. 950, TUV EN 60950, CB Scheme to IEC
60950 with full deviations |
UL 1950, CSA C22.2 No. 950, TUV EN 60950, CB Scheme (Nordic
Deviation) |
UL 1950, CSA C22.2 No. 950, TUV EN 60950, CB Scheme to IEC
60950 with full deviations |
RFI/EMI |
FCC Class A, DOC Class A, EN 55022/CISPR 22 Class A, VCCI
Class A |
FCC Class A, DOC Class A, EN 55022/CISPR 22 Class A, VCCI
Class A |
FCC Class A, DOC Class A, EN 55022/CISPR 22 Class A, VCCI
Class A |
Immunity |
CISPR 24 (EN 55024) |
CISPR 24 (EN 55024) |
CISPR 24 (EN 55024) |
Dimensions and Weights
|
N8400 Filer Controller (E420R) |
N8600 Filer Controller
(E4500) |
N8400/N8600 Filer Array
(T3) |
Height |
17.8 cm (7.0 in.) |
34.0 cm (13.5 in.) |
14.0 cm (5.5 in.) (3.5U) |
Width |
44.9 cm (17.2 in.) |
50.0 cm (19.7 in.) |
44.5 cm (17.5 in.) |
Depth |
69.6 cm (27.2 in.) |
56.0 cm (22.0 in.) |
47.0 cm (18.5 in.) |
Weight |
29.5 kg (65.0 lb.) (Shipping Weight) |
68 kg (150.0 lb. approximate) |
30.2 kg (67.0 lb. maximum, with half-height drives) |