This section provides the most common repair procedures for the
Netra 20, which are included in the following manual:
Component |
Remove
|
Install
|
Tips |
CPU Fan Assembly |
7-5
|
7-7
|
|
CPU Module |
9-4
|
9-7
|
- Guidelines for understanding and diagnosing UltraSPARC III Level 2
(L2) SRAM Cache Memory Errors (FIN I0887-1).
|
Disk Drive (Hot Swap)
|
8-2
|
8-4
|
- Seagate ST336605FC 36GB and ST373405FC 73G drives could be susceptible
to label corruption (FIN I0816-1).
- Recovering from a failed FCAL boot disk (SRDB 17643).
|
Disk Drive (Unmirrored Root Disk) |
8-5
|
8-6
|
- Seagate ST336605FC 36GB and ST373405FC 73G drives could be susceptible
to label corruption (FIN I0816-1).
- Recovering from a failed FCAL boot disk (SRDB 17643).
|
Graphics Card |
-
|
-
|
- XVR-500 Graphics Accelerator card does not function properly in Netra
20 servers (FIN I0900-1).
|
LOMLite2 Card |
9-15
|
9-15
|
|
Memory |
9-9
|
9-11
|
- Too many Memory DIMMs are being unnecessarily replaced on UltraSPARC
III family of systems utilizing NG-DIMM memory (FIN I0760-1).
|
PCI Card |
9-3
|
9-3
|
- UltraSPARC III systems may panic due to a conflict between the Schizo
2.4 ASIC and the GigaSwift Ethernet PCI Card (FIN I0874-1).
|
Power Distribution Board |
6-4
|
6-6
|
|
Power Supply Unit |
6-1
|
6-3
|
|
PSU Fans |
7-3
|
7-4
|
|
Replaceable Batter |
9-12
|
9-13
|
|
System Configuration Card Reader |
9-16
|
9-17
|
|
System Board |
9-18
|
9-23
|
- UltraSPARC III and III+ based platforms could be susceptible to UCC
errors that may cause system panics (FIN I0856-1).
|