FIN
|
Impl.
|
Components
Affected |
Description |
I0757-1 |
C
|
Ethernet RIO Interface (eri) driver |
Sun Servers which utilize the "eri" driver could be susceptible to Ethernet
link errors or hangs. |
I0755-1 |
C
|
CPU modules |
Tuning the ecache_scan_rate
parameter of the Solaris cache scrubber provides improved Ecache parity
error protection on non-mirrored SRAM UltraSPARC II-based systems. |
I0733-1 |
R
|
UltraSPARC IIe processor support code |
Netra X1 and Netra T1 AC200/DC200 servers may experience a system hang
or system crash. |
I0724-2 |
R
|
18 GB and 36 GB IBM disk drives |
Failure analysis results have
highlighted a significant failure rate for Drive Not Ready (DNR) on returned
IBM 18GB & 36GB disk drives. These failures have been observed to occur
as a result of the disk drives either been stored or operated in an extremely
hot and humid environments. |
I0695-1 |
R
|
OBP/Booting |
Netra X1/Netra T1 AC200/DC200 server has been shipped with the diag switch
within the OBP set to true with OBP V4.0.6 (Netra X1) and with OBP V4.0.3
(Netra T1 AC200/DC200) or lesser versions. |
I0655-1 |
R
|
Solaris 8 10/00 or Solaris 8 01/01 |
A reinstallation of Solaris 8 10/00 or Solaris 8 01/01 can cause a rare
but possible silent data corruption. |