Netra[tm] T1 AC200 / DC200 Servers: Repair Procedures
This section provides the most common repair procedures for the
Netra T1 AC200/DC200, which are included in the following manual:
Netra T1 AC200 and DC200 Server User's Guide (806-5978)
The following table provides the page numbers for
each procedure.
Component |
Remove
|
Install
|
Tips |
CD-ROM Drive |
4-9
|
4-7
|
|
DC Input Power Cable |
-
|
3-3
|
|
Disk Drive
|
4-2
|
4-2
|
- When inserting a hard disk drive into its enclosure, make sure the
top of the disk drive is touching the top of the enclosure. If you try
to install it with the bottom of the disk drive touching the bottom
of the enclosure, the drive will not align with the slide rails inside
the encloser, and you will not be able to insert the drive. (Product
Notes, 806-6134)
- 18.2GB and 36GB IBM disk drives may be susceptible to early life failures
problem (FIN I0724-2).
- 18GB and 36GB IBM disk drives experiencing high failure rate in high
humidity and high temperature environments (FCO A0182-1).
|
Fan Assembly (Rear, 1 and 2) |
11-16
|
11-16
|
|
Fan Assembly (CPU Fan, 3) |
11-18
|
11-18
|
|
Memory |
4-10
|
4-10
|
|
Netra T1 AC200 (entire system) |
11-2
|
11-2
|
- This procedure provides instructions to replace an entire system,
because you can re-use an old server's MAC address, serial number, and
NVRAM settings into the new system.
|
NVRAM |
11-8
|
11-8
|
|
PCI Card |
4-14
|
4-11
|
|
Power Supply |
11-14
|
11-14
|
|
System Configuration Card Reader |
11-4
|
11-4
|
|
System Board |
11-11
|
11-12
|
|
|