Sun Microsystems, Inc.
spacer spacer
spacer   Sun System Handbook Home | Systems | Components | General Info | Search | Feedback 
spacer
black dot
 
black fade
 

FDDI/DX

Sun-4/110/150/260/280/330/350/390/470/490
SS630MP / SS670MP / SS690MP

Option 461
501-1276



Power:

11.2 Amps @ +5Vdc
0.1 Amps @ -5Vdc
1.9 Amps @ +12Vdc
0.7 Amps @ -12Vdc
87.7 Watts

Switch Settings


Notes

  1. Use 2A subminiature Fuse 150-1174.
  2. The Sun 3004 CPU must be 501-1163-09, 501-1164-09 or greater. All 501-1208 revisions are usable.
  3. 501-1276-02 or greater is required for use with the SunLink Channel Adapter board.
  4. The Sun-4/330 requires Power Supply 300-1072.
  5. Set the FDDI Controller Switch 1, Dip 1, to ON if the DMA uses 32-bit addresses. All Sun systems use 32-bit DMA.
  6. Set the FDDI Controller Switch 1, Dip 1, to OFF if the DMA uses 24-bit addresses.

Release Notes

  1. Diskless booting requires CPU EPROM 3.0 or greater.
  2. The minimum operating system is SunOS 4.0.3.
  3. The FDDI/DX is not supported in Solaris >=2.2.

Reference

SunLight FDDI Dual-Attach Controller Card Configuration and Installation Manual, 813-1053.


Last updated: December 2, 1996
WebToneWebToneWebToneWebTone
 Copyright 1994-2003 Sun Microsystems, Inc.,  901 San Antonio Road, Palo Alto, CA 94303 USA.  All rights reserved.
 Legal Terms Privacy Policy Feedback