VMEbus to Multibus Adapter
with Systech MTI-1650
Sun-4/260/360
Option 481
501-1157-02
Power:
- 7.1 Amps @ +5Vdc
- 0.6 Amps @ +12Vdc
- 0.4 Amps @ -12Vdc
- 47.5 Watts
VME TO MULTIBUS ADAPTER BOARD SWITCH SETTINGS |
SWITCH |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
DESCRIPTION |
U1* |
N/C |
ON |
ON |
ON |
ON |
ON |
OFF |
OFF |
I-O Address |
U2 |
N/C |
ON |
ON |
ON |
ON |
ON |
OFF |
OFF |
I-O Space = 2 |
U3 |
ON |
ON |
ON |
ON |
ON |
OFF |
OFF |
ON |
I-O Address = 0xEE |
U4 |
ON |
ON |
ON |
ON |
ON |
OFF |
OFF |
ON |
VME I-O Space |
U5 |
ON |
ON |
ON |
ON |
ON |
ON |
ON |
ON |
24-Bit Memory Address Space |
U6 |
OFF |
OFF |
OFF |
OFF |
OFF |
OFF |
OFF |
OFF |
24-Bit Memory Block Size |
U7 |
ON |
ON |
ON |
ON |
ON |
ON |
ON |
ON |
24-Bit Memory Address Space |
U8 |
OFF |
OFF |
OFF |
OFF |
OFF |
OFF |
OFF |
OFF |
24-Bit Memory Block Size |
U9 |
OFF |
OFF |
OFF |
OFF |
OFF |
OFF |
OFF |
OFF |
No connection |
U10 |
OFF |
OFF |
OFF |
OFF |
OFF |
OFF |
OFF |
OFF |
No connection |
U11 |
OFF |
OFF |
OFF |
OFF |
ON |
ON |
ON |
ON |
Sets Address Bits A23 - A20 |
U12* |
ON |
ON |
ON |
ON |
OFF |
ON |
ON |
OFF |
Interrupt Vector |
J1 |
PINS 1-2 |
IN |
If BCLK is desired |
PINS 3-4 |
IN |
If CCLK is desired |
* mti1, U1, 2,4,5,6, ON, U12, 2,3,5,6,7, ON
mti2, U1, 2,5,6, ON, U12, 1,3,5,6,7, ON