CDC 94171-327/344 (327MB)
5 1/4" 3600 RPM Embedded SCSI Sun-4/330/370/470
Options RREXP-P7 / RR129 / RR134 Options 526 / 527 / 530 / 539
555-1005
|
370-1153 |
370-1230 |
w Bracket
w/o Bezel
77777107 |
w/o Bracket
w/o Bezel 77777107
3 1/4" Height |
w/o Bracket
w Bezel 77777126 3 1/4" Height |
End View
Ground Select Jumper J3
Drive Select and Option Select Jumper J4
In the External Storage Module, orient the Address Select Switch Cable as
shown, and plug it into J4.
Terminator Power Source Select Jumper J5
Power
- 1.5 Amps @ +5Vdc
- 1.4 Amps @ +12Vdc
- 24.3 Watts
Jumper Settings
555-1005 and 370-1153 Only
J3
PIN
|
SETTING |
DESCRIPTION |
1-2 |
In |
AC + DC ground connected to signal ground |
3-4 |
In |
AC + DC ground connected to chassis ground |
J4
PIN |
SETTING |
DESCRIPTION |
P |
In |
Parity enabled |
J5
PIN |
SETTING |
DESCRIPTION |
3-4 |
In |
Terminator power from DC connector |
370-1230 Only
J3
PIN |
SETTING |
DESCRIPTION |
1-2 |
Out |
AC + DC ground not connected to signal ground |
3-4 |
Out |
AC + DC ground not connected to chassis ground |
J4
PIN
|
SETTING |
DESCRIPTION |
P |
Out |
Parity enabled |
J5
PIN |
SETTING |
DESCRIPTION |
3-4 |
In |
Terminator power from DC connector |
Address Jumper Settings
J4
PIN |
SETTING |
DESCRIPTION |
TARGET |
1, 2, 4 |
Out |
Drive select |
Target 0 |
1 |
In |
Drive select |
Target 1 |
2 |
In |
Drive select |
Target 2 |
1, 2 |
In |
Drive select |
Target 3 |
Notes
- Remove the terminators from the underside of the drive.
- Terminate the Sun386i with external terminator 530-1381.
- Sun-3/470, Sun-4/370, and Sun-4/470 systems with dual option trays are
terminated internally on the 501-1493 Interface PCB. The left side tray must be
installed to terminate the SCSI bus.
- Sun-4/370 and Sun-4/470 systems with a single option tray are terminated
externally with terminator 150-1346.
- Terminate the External Storage Module with terminators 530-1381 or
150-1785.
- Terminate the Sun-4/330 on the SCSI-Out PCB with three 220/330 terminators,
120-1608-01.
Format Utility Notes
- The 94171-327 has fewer cylinders than the 94171-344.
- The SunOS 4.x format utility fails if the 94171-327 is used with
the standard format.dat entry on any system other than a Sun386i.
- Use the following format.dat entry for the 94171-327 on SunOS 4.x.
disk_type = "CDC Wren IV 94171-327" \
: ctlr = SCSI : fmt_time = 4 : cache = 0x11: trks_zone = 9 \
: asect = 3 : ncyl = 1520 : acyl = 2 : pcyl = 1549 : nhead = 9 \
: nsect = 46 : rpm = 3600 : bpt = 20833
- Solaris 2.x includes an entry for the 94171-327 in format.dat.
Remove the comment symbol "#" to use the entry.
References
- 386i Field Service Manual, 814-0002-10.
- 327MB Embedded SCSI Configuration Procedures, 814-1015-01.
- 5 1/4-Inch Disk Drive Installation in the 12-Slot Office Pedestal
Manual, 813-1055-10.
- Sun 327 Mbyte SCSI Disk Configuration Manual, 813-2048-03.
Last updated: December 2, 1996
|