Seagate 97229-11G (911MB)

Equipment Number PA8Y2

8" 3600 RPM IPI-2 6MB/Sec

Options 716 / 717 / 719 / 720 / 741L / 742L / 743L / 744L / 745L

Operator Panel
370-1355



Note

Each drive power-on sequence is delayed for a time equal to five seconds times its address. For example, if the address is 3, the drive starts after a 15-second delay.


Disk Enclosure

370-1351 370-1352 540-2005 540-2008
Rackmount Disk
w/o Power Supply
w/o Tray
Pedestal Disk
w/o Bracket
Rackmount Disk
w Power Supply
w Tray
Pedestal Disk
w Bracket

Control Board Dip Switch Settings

Dip Switch 1, Switches 1,2,3,4
DRIVE SWITCH 4 SWITCH 3 SWITCH 2 SWITCH 1
0 Closed Closed Closed Closed
1 Closed Closed Closed Open
2 Closed Closed Open Closed
3 Closed Closed Open Open
4 Closed Open Closed Closed
5 Closed Open Closed Open
6 Closed Open Open Closed
7 Closed Open Open Open

Dip Switch 1, Switches 5 and 6
SWITCH DESCRIPTION
5 Not used
6 Open = Write protected
Closed = Write enabled



I/O Board Rear View

Power Connector
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
+24
RTN
+24 +24 +24 +24
RTN
+24
RTN
N/C PWR
OK
-12 -5 -5 GND GND +5 +5

Dip Switch 1 Settings
SWITCH SETTING DESCRIPTION
1
2
3
4
Open
Closed
Open
Closed
Drive starts when DC Power is applied
Disable Port B
Enable Port A
Disable internal diagnostics
5
6
7
8
Open
Closed
Open
Closed
1D 3
1D 2
1D 1
1D 0
ID Microcode. Do Not Change
"
"
"
9 Open Slave/Master spindle sync-slave

Notes

  1. The 911MB Disk requires minimum ISP-80 firmware 525-1023-05, 525-1024-07, and 525-1025-07.
  2. ISP-80 501-1539-05 and 501-1855-01 contain the minimum firmware required by the 911MB Disk.
  3. Upgrade lower revision ISP-80 Controller boards with Option X2080A.
  4. Use terminator 370-1220-01 on the Port A/B Out connector.
  5. Disable an unused port with the Port Enable/Disable switch.
  6. Do not install a terminator on an unused port.
  7. There are cooling vents on the cover of 911MB Drive 370-1351. Do not install this drive in the Sun Expansion Pedestal.
  8. There are no cooling vents on the cover of 911MB Drive 370-1352. Do not install this drive in the Sun 56" Rack.
  9. Power Supply 300-1052 does not support the 911MB Drive.
  10. Use Power Supply 300-1075 in the Sun Expansion Pedestal.

References

  1. IPI8-1000/2HP Disk Drive Configuration and Installation Procedures for the Sun Expansion Pedestal, 813-5377-11.
  2. PI8-1000 and IPI8-1000/2HP Disk Drive Configuration and Installation Procedures for the Sun 56-inch Cabinets, 813-1109-10.


Last updated: December 2, 1996