Sun StorEdge[tm] 3900/6900: Field Change Orders
Implementation (Impl.):
M = Mandatory (Fully Pro-Active)
C = Controlled Pro-Active (per Sun Geo Plan)
U = Upon Failure |
For Netra[tm] X1 specific FCOs, click here.
For Sun Fire[tm] V100 specific FCOs, click here.
For Sun StorEdge T3 array specific FCOs, click here.
FCO
|
Impl.
|
Components
Affected |
Description |
A0203-1
|
C
|
Sun StorEdge 6910
Sun StorEdge 6960 |
Some StorEdge 6910 and 6960 storage systems have an AC power
misconnection, which allows a single point of failure of the AC line power
into either the front or rear PDU. A single PDU failure (either front or
rear), or a failure of AC line power into either the front or rear PDU could
cause a system down condition. |
|