Components Affected Description
A0199-2
C
18GB FCAL disk Seagate ST318203FC (540-4440-01)
18GB FCAL disk Seagate ST318304FC (540-4673-01)
36GB FCAL disk Seagate ST136403FC (540-4367-01)
18GB FCAL disk Seagate ST318203FC (540-4191-01)
9GB FCAL disk Seagate ST39102FC (540-3869-01)
36GB FCAL disk Seagate ST136403FC (540-4192-01)
Seagate Cheetah 3 FCAL disk drives may experience higher than expected failure rate.
A0183-1
C
325W Pwr Sply w/NiMH Battery (300-1454-01)
325W Pwr Sply w/NiMH Battery (370-3956-01)
Sun StorEdge T3 Arrays shipped prior to December 31, 2000 may experience early life failures of their Power Cooling Unit (PCU) Battery Packs.
A0182-1
C
18GB and 36GB IBM disk drives 18GB and 36GB IBM disk drives experiencing high failure rate in high humidity and high temperature environments.
A0175-1
C
T3 Array Controller (375-0084-01)

Sun StorEdge T3 (Purple) Arrays shipped prior to General Availability have the potential of experiencing intermittent parity or 'no cache found' errors. Sun StorEdge T3 Arrays with hubs are not supported with controllers earlier than revision J7. Shown below are typical error messages:

  • 0 MBytes Cache Memory Detected
  • 125722 Cache memory parity error detected

To recover from the above failure the array would need to be rebooted. The problem results in a loss of data access, not actual data loss.

 