Sun StorEdge[tm] 9970/9980 Array: Field Information Notices

 

Implementation (Impl.):
M
= Mandatory (Fully Pro-Active)

C
= Controlled Pro-Active (per Sun Geo Plan)

R
= Reactive (As Required)

FIN
Impl.
Components Affected Description
I0919-1
R
HDS Raid Manager software Conflict between HDS Raid Manager software and MPXIO device pathnames on SE9900 Arrays.
I0915-1
R
'Unspecified Transport Error' StorEdge 9970/9980 Arrays fail initial discovery with 'Unspecified Transport Error'.
I0914-1
R
No Reboot After Power Failure SE9900 Arrays do not automatically reboot and return to full functionality following a power outage.
I0913-1
R
Microcode Information SE9900: available online Microcode information.
I0904-1
R
Seagate DKS2B-K36FC Disk Drives Seagate DKS2B-K36FC disk drives are being unnecessarily replaced in StorEdge 9970/9980 Arrays with DKCMAIN microcode level less than 21-02-45-00/00.
I0903-1
R
Configuration Diskettes The propagation of SE9900 configuration diskettes from one SE9900 Subsystem to another, can result in a complete SE9900 subsystem outage.
I0889-1
C
SBus Dual FC Network Adapter (X6757A, 375-3048)
All StorEdge 99XX Arrays
A potential for data loss exists with SBus Fibre Channel Adapters (6757A) attached to Sun StorEdge 99xx arrays or to Fibre Channel Tape drives in specific configurations.