FCO
|
Impl.
|
Components
Affected |
Description |
A0182-1 |
C
|
18GB and 36GB IBM disk drives |
18GB and 36GB IBM disk drives experiencing
high failure rate in high humidity and high temperature environments. |
A0163-1 |
C
|
Differential Ultra/Wide SCSI
UDWIS/S (370-2443-01) |
Systems with large quantities of UDWIS/SBus
Host Adapters installed may not come up after reboot due to miscommunication
between the SCSI host and the target. Large configurations with many UDWIS/SBus
Host Adapter cards are more vulnerable due to higher probability of encountering
the reboot problem. If a system can be rebooted it may fail to communicate
correctly with a storage device connected via a UDWIS/SBus Host Adapter.
This would have different results depending on the system configuration. |
A0162-1 |
C
|
360 watt power supply
FDK PEX737-30 (300-1340-03) |
Storage A1000 or D1000 (Dilbert) Power
supplies fail with amber LED. Since the Storage A1000 or D1000 has two power
supplies and are redundant, the system will continue to run with one failed
power supply. A total of 7217 affected Dilberts shipped with 14,434 affected
power supplies between June 1998 and October 1999. It is estimated that
66% of these 7217 Dilberts will experience a power supply failure due to
this issue within three years from the time they are put into service. |