FIN |
Impl.
|
Components
Affected |
Description |
I0755-1 |
C
|
CPU modules |
Tuning the ecache_scan_rate
parameter of the Solaris cache scrubber provides improved Ecache parity
error protection on non-mirrored SRAM UltraSPARC II-based systems. |
I0743-1 |
R
|
Rackmounting |
Rack-mounted Enterprise 220R,
420R and Sun Fire 280R systems may bind with adjacent systems if improperly
installed. |
I0723-1 |
C
|
Toshiba DVD-ROM SD-M1401 (390-0025-01)
|
Toshiba DVD-ROM drives (390-0025-01) cannot
boot future Solaris releases from DVD media without a firmware patch. |
I0666-1 |
R
|
380W Power Supply (300-1449-02 & 300-1449-03) |
New replacement procedures for defective
E220R/E420R system power supplies. |
I0616-1 |
C
|
CPU Module |
Solaris kernel patches provide improved
handling and reduction of CPU, Ecache, and main memory errors in UltraSPARC
systems. All customers on Solaris 2.5.1, 2.6, 7 and 8 are encouraged to
consider upgrading to these kernel patches as they become available. |
I0592-1 |
C
|
SRC/P Intelligent SCSI RAID Controller
(375-0078-01, 375-0078-02) |
Numerous error conditions may result from
using the StorEdge SRC/P RAID controller with Firmware Version SM02. |
I0570-3 |
R
|
CPU Modules |
The current diagnostic procedure
to identify the faulty CPU module from CPU Ecache parity errors is flawed,
and could easily lead to the wrong CPU being replaced. Make sure to follow
the appropriate instructions and guidelines to CORRECTLY identify Ecache
panic fault diagnosis on multi-cpu systems. |