FIN
|
Impl.
|
Components
Affected |
Description |
I0900-1 |
R
|
XVR-500 Graphics Accelerator (375-3069-01) |
XVR-500 Graphics Accelerator card does not function properly in Netra
20 servers. |
I0887-1 |
R
|
ASSY CPU-4PROC USIIIP 900+ MHz (540-5052-02 or lower)
ASSY CPU-2PROC USIII 750MHz (540-4729-04 or lower)
ASSY CPU-4PROC USIII 750MHz (540-4730-04 or lower)
ASSY CPU-2PROC USIIIP 900+ MHz (540-5051-02 or lower)
ASSY CPU DUAL 750MHz AL A30 (501-5818-06 or lower)
ASSY CPU-4GB/4PROC USIII 900+ MHz (540-4934-03 or lower)
ASSY CPU-8GB/4PROC USIII 900+ MHz (540-4992-02 or lower)
ASSY CPU-16GB/4PROC USIII 900+ MHz (540-4990-03 or lower)
ASSY CPU-32GB/4PROC USIII 900+ MHz (540-4993-02 or )
ASSY CPU-2GB/2PROC USIII 900+ MHz (540-4984-02 or lower) |
Guidelines for understanding and diagnosing UltraSPARC III Level 2 (L2)
SRAM Cache Memory Errors. |
I0874-1 |
R
|
Gigabit Ethernet (501-5209-07 or lower) |
UltraSPARC III systems may panic due to a conflict between
the Schizo 2.4 ASIC and the GigaSwift Ethernet PCI Card. |
I0867-1 |
R
|
System Config Card (370-5155) |
Replacement of the System Configuration Card (SCC) in Netra
20 systems previously resulted in extended system downtime because the board
was not orderable as a FRU. Delays of many days could be encountered in
ordering a replacment part via the non-FRU process. |
I0864-1 |
R
|
OBP 4.6.{0-6} with Solaris 9 update 1 or later |
Multiple-CPU systems based on the Safari Bus which run OBP
version 4.6.{0-6} and Solaris 9 Update 1 (09/02) or later versions may fail
to boot due to an interrupt problem. On Sun Blade 1000 and Sun Blade 2000
systems, a boot of Solaris will hang when the second CPU is brought online.
Other Safari Bus platforms running OBP 4.6.{0-6} may also be affected by
this issue, although no failures have been reported. |
I0856-1 |
C
|
ASSY CPU-4PROC USIIIP 900+ MHz (540-5052-02 or below)
ASSY CPU-2PROC USIII 750MHz (540-4729-04 or below)
ASSY CPU-4PROC USIII 750MHz (540-4730-04 or below)
ASSY CPU-2PROC USIIIP 900+ MHz (540-5051-02 or below)
ASSY CPU DUAL 750MHz AL A30 (501-5818-06 or below)
ASSY CPU-4GB/4PROC USIII 900+ MHz (540-4934-03 or below)
ASSY CPU-8GB/4PROC USIII 900+ MHz (540-4992-02 or below)
ASSY CPU-16GB/4PROC USIII 900+ MHz (540-4990-03 or below)
ASSY CPU-32GB/4PROC USIII 900+ MHz (540-4993-02 or below)
ASSY CPU-2GB/2PROC USIII 900+ MHz (540-4984-02 or below) |
UltraSPARC III based platforms could be susceptible to Correctable
Fast ECC (UCC) errors that could cause a system panic resulting in loss
of service of the system. Any UltraSPARC III based server running Solaris
8 without PatchId 108528-15 can be affected. Systems running Solaris 9 are
not affected, and pre-Solaris 8 is not supported on these platforms. This
issue has typically been seen on 900MHz UltraSPARC III based processors,
although other UltraSPARC III based processors have been impacted as well. |
I0832-1 |
R
|
Assembly, Shroud (540-4136-06) |
CPU shroud inserts for Sun Blade 1000, Sun Blade 2000, Netra
20 (T4) or Sun Fire 280R systems may have been improperly installed during
manufacture. The four CPU shroud inserts (to which the CPU module captive
screws attach) may exhibit angles greater than the specified .5 degree from
vertical, thus causing increased resistance during insertion/removal of
the CPUs. |
I0816-1 |
C
|
Seagate 36GB disk (540-4525-01), Seagate 73GB disk (540-4905-01) |
Seagate ST336605FC 36GB and ST373405FC 73G drives could be
susceptible to label corruption. |
I0806-1 |
R
|
OBP and POST |
Sun Blade 1000, Sun Fire 280R and Netra 20 (T4) systems with
certain OBP revisions may fail POST with "Scan Chain Broken" error messages. |
I0760-1 |
R
|
Memory DIMMs |
Too many Memory DIMMs are being unnecessarily replaced on UltraSPARC III
family of systems utilizing NG-DIMM memory |
I0735-1 |
R
|
Netra LOM 2.0 Software |
Successful operation of the Netra LOM 2.0 Software on Netra 20 (T4) systems
requires Patch 110208-11 or later. |
I0722-1 |
R
|
PGX32 CARD (X3668A)
SunBlade 1000 System Board (501-4143-15 or lower)
SunBlade 1000/Sun Fire 280R System Board (501-5938-07 or lower)
Sun Fire 3800 cPCI I/O ASSY (540-4591-01)
Sun Fire 4800/4810/6800 PCI I/O ASSY (540-4616-01)
Sun Fire 4800/4810/6800 cPCI I/O ASSY (540-4617-03) |
If the Emulex FC HBA card is placed on the same PCI Bus with any other
PCI card which causes the Schizo chip to attempt a 64-bit PIO, a system
panic would most likely result. The problem will not occur if the Emulex
HBA card is installed alone on a PCI Bus. UltraSparc-III platforms utilizing
the Schizo 2.1 or 2.2 ASIC may experience panics due to address parity
errors on the PCI Bus. The problem has been seen on the Sun Fire 280R
with the Emulex FC HBA card in combination with a PGX32 card installed
on the same PCI Bus. This condition occurs when a card on the PCI Bus
detects a 64-bit parity address error on the PCI Bus while another card
on the same PCI Bus is performing a 64-bit PIO. The following error messages
are displayed prior to a system panic:
WARNING: pcisch-0: PCI fault log start:
PCI SERR
PCI error ocurred on device #6
dwordmask=0 bytemask=0 PCI primary error (0):
pcisch-0: PCI secondary error (0):
pcisch-0: PBM AFAR 0.00000000:
pcisch-0: PCI config space error status (4280):
signalled system error. pcisch-0:
PCI fault log end.
panic[cpu1]/thread=2a10000bd40: pcisch-0: PCI bus 2 error(s)!
|