Racking |
Fits into 19-, 23-, 24-in., 600-mm racks (requires mounting
kit,19-in.flanges supplied with product, others available as options) |
Processor |
Number |
Up to four |
Architecture |
440-MHz, 64-bit, UltraSPARC II |
Cache memory |
16 KB data and 16 KB instruction on chip
Secondary: 4 MB external (per CPU module)
|
Main
Memory |
Capacities |
Total of 16 DIMM memory slots available
Up to 4 GB (DIMMS must be installed in sets of four)
|
Standard
Interfaces |
Alarm card |
One alarm port (DB15)
with relay connections for for Ethernet, ATM, and serial I/O
One RS-232/RS-423 asynchronous LOM port (RJ-45)
|
Ethernet |
One ethernet/fast ethernet (10BASE-T/100BASE-T) shielded twisted-pair
port (RJ-45) |
Keyboard and mouse |
One standard keyboard/mouse port (mini
DIN-8 ) (this is not an NEBS compliant port) |
Parallel |
One Centronics-compatible parallel port (DB25);
ECP mode capable |
PCI |
Four full-size PCI 2.1 compliant slots:
- Slot 1: 64-bit, 33- or 66-MHz, 5.0/3.3 V
- Slots 2 & 3: 32- or 64-bit, 33-MHz, 5.0/3.3 V
- Slot 4: 32-bit, 33-MHz, 5.0/3.3 V
|
SCSI |
One 40-MB/sec, 68-pin,
UltraSCSI (SCSI-3) port |
Serial |
Two RS-232/RS-423 asynchronous/synchronous serial ports (DB25) |
SCSI |
40-MB/sec.Ultra SCSI |
Internal
Mass Storage |
Disks |
Up to four 18-or 36-GB disks |
CD-ROM/DVD-ROM |
Optional SunCD 32
Optional 10X-speed DVD-ROM, equivalent to 40X-speed CD-ROM
|
Tape |
Optional 12-to 24-GB DDS3, 4 mm |
Power
Supply |
AC power (Netra t 1405) |
Three (n +1 redundant) AC power supplies
100/240 V AC nominal,330 W,dual input |
DC power (Netra t 1400) |
Three (n +1 redundant) DC power supplies
48/60 V DC nominal,330 W,dual input |
Environment |
AC input |
90 - 264 VAC, 47 - 63 Hz, 4 A, 0.4 KVA
|
DC input |
-48 to -60 VDC, 10 A @ -48 VDC, 12 A @ -60 VDC |
Heat output |
2254 BTU/hr |
Temperature 1 |
Operating: 5° C to 40° C (41° F to 104° F)
Operating (short term): -5° C to 55° C (23° F to 131° F)
Nonoperating: -40° C to 70° C (-40° F to 158° F)
|
Humidity |
Operating: 5% to 85% relative humidity, noncondensing
Nonoperating: 10% to 95% relative humidity, noncondensing |
Altitude |
Operating: -300 m to 3000 m (-1000 ft. to 10,000 ft.)
Nonoperating: -300 m to 12,000 m (-1000 ft. to 40,000 ft.) |
ETSI |
ETS 300-19-2-3 |
Acoustic noise |
Operating: <60dBA
Idling: <60dBA |
Seismic |
Meets GR-63-CORE requirements for earthquake risk zone 4
Meets ETS 300-19-2-3, A1 operating requirements
|
Number of cords |
3 |
Plug type - U.S. |
NEMA 5-15P |
1 - Short term is defined as no more than 96 hours duration
at extremes and at elevations less than 1800m.
|
Regulations
Meets or exceeds the following requirements: |
Safety |
UL 1950/CSA C22.2 No.950, EN 60950 (73/23/EEC), IEC 950 |
Emissions |
CFR Title 47 FCC Part 15, EN 55022 (89/336/EEC), (EN61000-3-2, Netra t
1405 only), Low Voltage Directive (73/23/EEC), CE Mark (93/68/EEC) |
Immunity |
Directive (73/23/EEC), CE Mark (93/68/EEC) |
Certification |
Safety: cULus Mark, GS Mark (Netra t 1405 only), CE Mark, Bauart
Mark (Netra t 1400 only) EMC CE Mark (93/68/EEC), FCC authorized Class
A
|
Dimensions
and Weights |
Height |
26.4 cm (10.4 in./6U) |
Width |
43.18 cm (17 in.) |
Depth |
50.47 cm (19.9 in.) |
Weight |
37 kg (81.8 lbs.) |