Processor |
Number |
Up to two |
Architecture |
750-MHz UltraSPARC[tm] III,
900-MHz UltraSPARC III Cu, or
1015-MHz UltraSPARC III Cu
|
Memory Management |
MMU with 64 I-TLB entries and 64 D-TLB entries, 8192 hardware-supported
contexts |
Cache memory |
64-KB data and 32-KB instruction on chip per processor
Secondary: 8-MB external per processor
|
Main
Memory |
Capacities |
Total of 8 DIMM memory slots available
128-, 256- or 512MB; or 1-GB expansion (8 GB maximum)
|
Memory type |
232-pin 7ns memory modules |
Standard
Interfaces |
Ethernet |
One ethernet/fast ethernet (10BASE-T/100BASE-T) twisted-pair standard
connector (RJ-45), autosensing,
autoswitching |
FC-AL |
One Fibre Channel-Arbitrated Loop (FC-AL), 8-pin,
port |
Keyboard and mouse |
USB (uses one of the four standard USB
(Type A) ports) |
Parallel |
One IEEE 1284-compatible (bidirectional) parallel port (DB25);
EPP and Centronic mode capable |
PCI |
Four full-size slots compliant with PCI specification version 2.1:
- One slot operating at 33- or 66-MHz, 32- or 64-bit data bus width,
3.3 volt
- Three slots operating at 33 MHz, 32- or 64-bit data bus width, 5 volt
|
SCSI |
One 40MB/sec, 68-pin
,UltraSCSI (SCSI-2) synchronous port |
Serial |
Two EIA-423/EIA-232D serial ports (DB25) |
USB |
Four standard Universal Serial Bus (USB)
Type A connectors |
Internal
Mass Storage |
Disks |
Up to two 3.5- x 1.0-in. fibre-channel disks (18GB/36GB/73GB formatted),
10,000 rpm |
DVD-ROM |
10X DVD-ROM (standard) |
CD-ROM |
Optional SunCD[tm] 32, 32X-speed, Photo CD compatible |
Tape |
Optional 12 to 24GB DDS3 4-mm, 14GB (DVD-ROM or CD-ROM must be removed) |
Power
Supplies |
Type |
One or two N+1 redundant, hot-swap universal input (one supply standard);
individual power cords |
Output |
560 W |
Power Bus |
Common, load-sharing |
Environment |
AC input |
100 - 240 VAC, 47 - 63 Hz, 9.2 A(max) |
Input power |
810 W |
Heat output |
3140 BTU/hr |
Temperature1 |
Operating: 5° C to 40° C (41° F to 104° F)
Nonoperating: -20° C to 60° C (-4° F to 140° F) |
Humidity |
Operating: 20% to 80% relative humidity, noncondensing
Nonoperating: 5% to 93% relative humidity, noncondensing |
Altitude |
Operating: 3000 m (10,000 ft.)
Nonoperating: 12,000 m (40,000 ft.) |
Acoustic noise |
Operating: 6.9 Bel |
Vibration |
Operating: 0.0002 G2/Hz, 5 - 500 Hz
(flat), z-axis only
Nonoperating: 0.0004 G2/Hz, 5 - 500 Hz
(flat), x-axis and y-axis
0.0008 G2/Hz, 5 - 500 Hz (flat), z-axis |
Shock |
Operating: 3G peak, 11 milliseconds half-sine pulse |
Number of cords |
2 max |
Plug type - U.S. |
NEMA 5-15P |
Plug type - International |
IEC 320, 10 A |
1 The front and
rear doors of the cabinet must be 63% open for adequate air flow. |
Regulations
Meets or exceeds the following requirements: |
Safety |
UL 1950, CSA C22.2 No. 950, TUV EN 60950, IEC 950 CB Scheme with full
deviation, including Nordic deviations EMKO-TSE (74-SEC) 203, ZH1/618 |
RFI/EMI |
FCC Class A, Industry Canada Class A, VCCI Class A, EN 55022 Class A,
EN 61000-3-2:1995, EN 61000-3-3:1995 |
Immunity |
EN 55024:1998 |
X-ray |
DHHS 21 Subchapter J; PTB German X-ray Decree |
Dimensions
and Weights |
Height |
17.6 cm (6.95 in.)
43.8 cm (17.25 in.) shipping |
Width |
43.8 cm (17.25 in.)
60 cm (23.63 in.) shipping |
Depth |
69.2 cm (27.25 in.)
94 cm (37.0 in.) shipping |
Weight |
34.0 kg (75.0 lb.)
38.6 kg (85.0 lb.) shipping |
Power cord |
1.99 m (6.56 ft.) |
Clearance
and Service Access |
Front1 |
91.4 cm (36 in.) |
Rear1 |
91.4 cm (36 in.) |
Right1 |
91.4 cm (36 in.) |
Left1 |
91.4 cm (36 in.) |
Top1 |
91.4 cm (36 in.) |
1These
specification s refer to a sytem that is fully extended from the rack for
service. When in normal operation, there are no side clearance requirements
for the server as the air flow is from the front to rear. However, make
sure that any front or back cabinet doors are 63% open to allow adequate
airflow. This can be accomplished by removing the doors, or ensuring that
the doors have a perforated pattern that provides a 63% open area. See 816-1613 for more details. |
Rack
Mounting |
Fits into a standard commercial 19-inch wide, 36-inch deep
rack |