Processor
Number Up to two
Architecture

750-MHz UltraSPARC[tm] III,
900-MHz UltraSPARC III Cu, or
1015-MHz UltraSPARC III Cu

Memory Management MMU with 64 I-TLB entries and 64 D-TLB entries, 8192 hardware-supported contexts
Cache memory

64-KB data and 32-KB instruction on chip per processor

Secondary: 8-MB external per processor

Main Memory
Capacities

Total of 8 DIMM memory slots available

128-, 256- or 512MB; or 1-GB expansion (8 GB maximum)

Memory type 232-pin 7ns memory modules
Standard Interfaces
Ethernet One ethernet/fast ethernet (10BASE-T/100BASE-T) twisted-pair standard connector (RJ-45), autosensing, autoswitching
FC-AL One Fibre Channel-Arbitrated Loop (FC-AL), 8-pin, port
Keyboard and mouse USB (uses one of the four standard USB (Type A) ports)
Parallel One IEEE 1284-compatible (bidirectional) parallel port (DB25); EPP and Centronic mode capable
PCI

Four full-size slots compliant with PCI specification version 2.1:

  • One slot operating at 33- or 66-MHz, 32- or 64-bit data bus width, 3.3 volt
  • Three slots operating at 33 MHz, 32- or 64-bit data bus width, 5 volt
SCSI One 40MB/sec, 68-pin ,UltraSCSI (SCSI-2) synchronous port
Serial Two EIA-423/EIA-232D serial ports (DB25)
USB Four standard Universal Serial Bus (USB) Type A connectors
Internal Mass Storage
Disks Up to two 3.5- x 1.0-in. fibre-channel disks (18GB/36GB/73GB formatted), 10,000 rpm
DVD-ROM 10X DVD-ROM (standard)
CD-ROM Optional SunCD[tm] 32, 32X-speed, Photo CD compatible
Tape Optional 12 to 24GB DDS3 4-mm, 14GB (DVD-ROM or CD-ROM must be removed)
Power Supplies
Type One or two N+1 redundant, hot-swap universal input (one supply standard); individual power cords
Output 560 W
Power Bus Common, load-sharing
Environment
AC input 100 - 240 VAC, 47 - 63 Hz, 9.2 A(max)
Input power 810 W
Heat output 3140 BTU/hr
Temperature1 Operating: 5° C to 40° C (41° F to 104° F)
Nonoperating: -20° C to 60° C (-4° F to 140° F)
Humidity Operating: 20% to 80% relative humidity, noncondensing
Nonoperating: 5% to 93% relative humidity, noncondensing
Altitude Operating: 3000 m (10,000 ft.)
Nonoperating: 12,000 m (40,000 ft.)
Acoustic noise Operating: 6.9 Bel
Vibration Operating: 0.0002 G2/Hz, 5 - 500 Hz (flat), z-axis only
Nonoperating: 0.0004 G2/Hz, 5 - 500 Hz (flat), x-axis and y-axis
0.0008 G2/Hz, 5 - 500 Hz (flat), z-axis
Shock Operating: 3G peak, 11 milliseconds half-sine pulse
Number of cords 2 max
Plug type - U.S. NEMA 5-15P
Plug type - International IEC 320, 10 A
1 The front and rear doors of the cabinet must be 63% open for adequate air flow.
Regulations
Meets or exceeds the following requirements:
Safety UL 1950, CSA C22.2 No. 950, TUV EN 60950, IEC 950 CB Scheme with full deviation, including Nordic deviations EMKO-TSE (74-SEC) 203, ZH1/618
RFI/EMI FCC Class A, Industry Canada Class A, VCCI Class A, EN 55022 Class A, EN 61000-3-2:1995, EN 61000-3-3:1995
Immunity EN 55024:1998
X-ray DHHS 21 Subchapter J; PTB German X-ray Decree
Dimensions and Weights
Height 17.6 cm (6.95 in.)
43.8 cm (17.25 in.) shipping
Width 43.8 cm (17.25 in.)
60 cm (23.63 in.) shipping
Depth 69.2 cm (27.25 in.)
94 cm (37.0 in.) shipping
Weight 34.0 kg (75.0 lb.)
38.6 kg (85.0 lb.) shipping
Power cord 1.99 m (6.56 ft.)
Clearance and Service Access
Front1 91.4 cm (36 in.)
Rear1 91.4 cm (36 in.)
Right1 91.4 cm (36 in.)
Left1 91.4 cm (36 in.)
Top1 91.4 cm (36 in.)
1These specification s refer to a sytem that is fully extended from the rack for service. When in normal operation, there are no side clearance requirements for the server as the air flow is from the front to rear. However, make sure that any front or back cabinet doors are 63% open to allow adequate airflow. This can be accomplished by removing the doors, or ensuring that the doors have a perforated pattern that provides a 63% open area. See 816-1613 for more details.
Rack Mounting
Fits into a standard commercial 19-inch wide, 36-inch deep rack