Processor |
Number |
Up to eight |
Architecture |
750 MHz UltraSPARC[tm] III (64-bit)
900 MHz UltraSPARC III (64 bit)
|
Memory Management |
MMU with 64 I-TLB entries and 64 D-TLB entries, 8192 hardware-supported
contexts |
Cache memory |
64-KB data and 32-KB instruction on chip per processor
Secondary: 8-MB external per processor
|
Main
Memory |
Capacities |
Total of 16 DIMM memory slots available per CPU/Memory board
128, 256, 512 MB, or 1GB* (16GB maximum per CPU/Memory board, 64GB maximum
when configured with 8 processors)
* - 1GB DIMMs only supported on 900MHz CPU/Memory boards.
Note: Install DIMMs in groups of four
|
Memory type |
232-Pin 7-nS memory modules |
Standard
Interfaces |
Ethernet |
- One Gigabit ethernet (1000BASE-T) dual SC fiber optic port
- One ethernet/fast ethernet (10BASE-T/100BASE-T) twisted-pair standard
connector (RJ-45)
|
Keyboard and mouse |
USB (uses one of the two standard USB
(Type A) port) |
PCI |
Nine full sized, hot-swap, PCI slots compliant with PCI specification
Revision 2.1:
- Two slots operating at 66-MHz, 64 or 32 bits wide, 3.3 volts
- Seven slot operating at 33-MHz, 64 or 32 bits wide, 5 volts
|
Remote System Controller |
One RSC card plugs into a dedicated slot on the system I/O board which
includes integrated modem, serial and Ethernet interfaces.
- One 56 Kbps modem port (RJ-11)
- One EIA-232D serial port (RJ-45)
- One 10 Mbps Ethernet port (RJ-45)
|
Serial |
Two RS-232D/RS-423 serial ports (DB25)
via splitter cable (X985A) |
USB |
Two standard Universal Serial Bus (USB)
Type A connectors |
Internal
Mass Storage |
Host Adapters |
Internal SCSI to support the internal DVD and optional removable media
devices
Up to nine PCI-to-dual FC-AL adapters or PCI-to-UltraSCSI adapters
|
Disks |
Up to 12 3.5" x 1" 10000 RPM FC-AL disks, 36.4GB,
or 73.4GB capacity. Maximum total capacity of 876GB. |
DVD-ROM |
10X DVD-ROM (standard) |
Tape |
Optional 12GB DDS3 4mm or 20GB DDS4 4mm single drive |
Power
Supplies |
Type |
2 minimum, 3 for N+1 redundancy, individual power cords |
Output |
1100W maximum per power supply |
Environment |
AC input |
100 - 240 VAC, 47 - 63 Hz, 15 A (max) per power cord, 1.48 KVA per power
supply (3.5 KVA) |
Input power |
3000 W |
Heat output |
Base Configuration: 2,867 BTU/hr
Maximum Configuration: 6,563 BTU/hr
See Infodoc 48584
for more specific details. |
Temperature |
Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -20° C to 60° C (-4° F to 140° F) |
Humidity |
Operating: 20% to 80% relative humidity, noncondensing
Nonoperating: 5% to 93% relative humidity, noncondensing |
Altitude |
Operating: 3000 m (10,000 ft.)
Nonoperating: 12,000 m (40,000 ft.) |
Acoustic noise |
Operating: 6.7 bels
Idling: 7.6 bels |
Vibration |
Operating: 0.0002 G2/Hz, 5 - 500 Hz
(random) (deskside)
0.00015 G2/Hz, 5 - 500 Hz (random) (rackmounted)
Nonoperating: 0.002 G2/Hz, 5 - 500 Hz (random)
(deskside)
0.0015 G2/Hz, 5 - 500 Hz (random) (rackmounted)
|
Shock |
Operating: 4 G peak, 11 milliseconds half-sine pulse (deskside)
3 G peak, 11 milliseconds half-sine pulse (rackmounted)
Nonoperating: 15 G peak, 11 milliseconds half-sine pulse (deskside)
10 G peak, 11 milliseconds half-sine pulse (rackmounted) |
Number of cords |
3 |
Plug type - U.S. |
NEMA 5-15P |
Plug type - International |
IEC 320, 10 A |
Regulations
Meets or exceeds the following requirements: |
Safety |
UL 60950, CSA C22.2, EN 60950 (from UL), TUV 60950, UL CB
Scheme IEC 950 (CE Mark), GOST |
RFI/EMI |
Class A:Australia/New Zealand AS/NZ 3548, Industry Canada
ICES-003,European Community EN55022/CISPR22,Japan VCCI,Taiwan CNS 13438,and
US FCC 47CFR15.B |
Immunity |
EN55024,i.e.EN61000-4-2,EN61000-4-3, EN61000-4-4,EN61000-4-5,EN61000-4-6,
EN61000-4-8,and EN61000-4-11 |
X-ray |
US DHHS 21 CFR Subchapter J, PTB German X-ray Decree |
Dimensions
and Weights |
Height1 |
71.4 cm (28.1 in.) with castors |
Width |
48.0 cm (18.9 in.) |
Depth |
83.6 cm (32.9 in.) |
Weight |
88.1 kg (194.0 lb.)(minimum, approximate)
130.9 kg (288.0 lb.)(maximum, approximate) |
Power Cord |
2.5 m (8.2 ft.) |
1 Rackmounting does
not require the removal of castors. |
Clearance
and Service Access |
Front |
Deskside - 91 cm (36 in.)
Rackmount - 122 cm (48 in.) |
Rear |
91 cm (36 in.) |
Right |
91 cm (36 in.) |
Left |
91 cm (36 in.) |
Rack
Mounting |
Fits into a standard commercial 19-inch wide, 36-inch deep
rack, but in third party racks, the front and rear doors must be at least
63% open area for the Sun Fire V880 to cool properly. To facilitate rack